Earticle

현재 위치 Home

Original Article

치과용 레진 연마를 위한 바렐 연마재의 성분 분석 및 표면 잔류물 관찰
Component and surface residue observation of barrel finishing media for grinding dental resins

첫 페이지 보기
  • 발행기관
    대한치과기공학회 바로가기
  • 간행물
    대한치과기공학회지 KCI 등재 바로가기
  • 통권
    Vol.43 No.4 (2021.12)바로가기
  • 페이지
    pp.145-152
  • 저자
    정안나, 박유진, 최성민
  • 언어
    한국어(KOR)
  • URL
    https://www.earticle.net/Article/A405022

※ 기관로그인 시 무료 이용이 가능합니다.

4,000원

원문정보

초록

영어
Purpose: This study aimed to produce resin prosthetics using a dental barrel finishing machine. For dental resin grinding, the ingredients of the barrel finishing media were analyzed, and surface residues of the resin were observed. Methods: Two types of barrel finishing media for dental resin grinding were tested. Specimens were made from thermal polymerized, auto polymerized, and photopolymerized resins. Finishing media were analyzed through energy-dispersive X-ray spectroscopy (EDS) component analysis and inductively coupled plasma-optical emission spectrometry (ICPOES) component analysis. Then, the prepared specimen was barrel finished for 25 minutes using two types of barrel finishing media, and scanning electron microscope was photographed to observe the surface residues. Results: As a result of EDS component analysis, both types of finishing media were analyzed for the components of C, O, Zr and Al elements, and industry media (IM) was further analyzed for the components of Si and Mg elements. In the ICP-OES component analysis, Cd and As, which are harmful elements, were detected in IM, and no harmful elements were detected in manufacturing media (MM). Because of observation of surface residues, no residues were observed in the three types of resin specimens that were barrel finished with two types of finishing media. Conclusion: Surface residue wasn’t observed on the specimens polished using two types of finishing media. However, in IM, Cd and As, which are harmful elements, were detected, making it inappropriate for clinical use. In MM, harmful elements were not detected; therefore, clinical use will be possible.

목차

Abstract
INTRODUCTION
MATERIALS AND METHODS
1. 실험재료
2. 시편 제작
3. 바렐 연마재의 표면 관찰 및 energy-dispersive X-ray spectroscopy (EDS) 성분 분석
4. 바렐 연마재의 inductively coupled plasma-optical emission spectrometry (ICP-OES) 성분 분석
5. 표면잔류물 관찰
RESULTS
1. 바렐 연마재의 표면 관찰 및 EDS 성분 분석 결과
2. 바렐 연마재의 ICP-OES 성분 분석 결과
3. 표면잔류물 관찰 결과
DISCUSSION
CONCLUSIONS
CONFLICT OF INTEREST
ORCID
REFERENCES

키워드

Barrel finishing Energy-dispersive X-ray spectroscopy Inductively coupled plasma-optical emission spectrometry Media Resin Scanning electron microscope

저자

  • 정안나 [ An-Na Jung | 부산가톨릭대학교 치기공학과 ]
  • 박유진 [ Yu-Jin Park | 부산가톨릭대학교 치기공학과 ]
  • 최성민 [ Sung-Min Choi | 부산가톨릭대학교 치기공학과 ] Corresponding Author

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    대한치과기공학회 [The Korean Academy Of Dental Technology]
  • 설립연도
    1979
  • 분야
    의약학>치의학
  • 소개
    본 학회는 치과기공에 관한 모든 분야의 연구와 회무를 총괄하기 위하여 세분화된 분과학회의 회원 상호간 학술교류와 정보를 수집하고, 보수교육 및 학술대회 준비, 진행과 학회지 발간등의 업무를 효율적으로 수행함을 목적으로 한다.

간행물

  • 간행물명
    대한치과기공학회지 [THE JOURNAL OF KOREAN ACADEMY OF DENTAL TECHNOLOGY]
  • 간기
    계간
  • pISSN
    1229-3954
  • eISSN
    2288-5218
  • 수록기간
    1979~2026
  • 등재여부
    KCI 등재
  • 십진분류
    KDC 515 DDC 617

이 권호 내 다른 논문 / 대한치과기공학회지 Vol.43 No.4

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장