Tristan Won, Ae-Kyoung Lee, Hyung-do Choi, Choonsik Lee
언어
영어(ENG)
URL
https://www.earticle.net/Article/A400234
원문정보
초록
영어
Background: In recent events of the coronavirus disease 2019 (COVID-19) pandemic, computed tomography (CT) scans are being globally used as a complement to the reverse-transcription polymerase chain reaction (RT-PCR) tests. It will be important to be aware of major organ dose levels, which are more relevant quantity to derive potential long-term adverse effect, for Korean pediatric and adult patients undergoing CT for COVID-19. Materials and Methods: We calculated organ dose conversion coefficients for Korean pediatric and adult CT patients directly from Korean pediatric and adult computational phantoms combined with Monte Carlo radiation transport techniques. We then estimated major organ doses delivered to the Korean child and adult patients undergoing CT for COVID-19 combining the dose conversion coefficients and the international survey data. We also compared our Korean dose conversion coefficients with those from Caucasian reference pediatric and adult phantoms. Results and Discussion: Based on the dose conversion coefficients we established in this study and the international survey data of COVID-19-related CT scans, we found that Korean 7-yearold child and adult males may receive about 4–32 mGy and 3–21 mGy of lung dose, respectively. We learned that the lung dose conversion coefficient for the Korean child phantom was up to 1.5-fold greater than that for the Korean adult phantom. We also found no substantial difference in dose conversion coefficients between Korean and Caucasian phantoms. Conclusion: We estimated radiation dose delivered to the Korean child and adult phantoms undergoing COVID-19-related CT examinations. The dose conversion coefficients derived for different CT scan types can be also used universally for other dosimetry studies concerning Korean CT scans. We also confirmed that the Caucasian-based CT organ dose calculation tools may be used for the Korean population with reasonable accuracy.
목차
ABSTRACT Introduction Materials and Methods 1. Korean Computational Human Phantoms 2. Organ Dose Calculation 3. Comparison of Dose Conversion Coefficients with Caucasian Data Results and Discussion 1. Organ Dose Coefficients for Korean Child and Adult Patients 2. Organ Doses for Korean Patients Undergoing COVID-19-Related CT 3. Comparison of Organ Dose Conversion Coefficients with Caucasian Data 4. Limitations Conclusion Conflict of Interest Acknowledgements Author Contribution References
Tristan Won [ Winston Churchill High School, Potomac, MD, USA ]
Ae-Kyoung Lee [ Radio & Satellite Research Division, Electronics and Telecommunications Research Institute, Daejeon, Korea ]
Hyung-do Choi [ Radio & Satellite Research Division, Electronics and Telecommunications Research Institute, Daejeon, Korea ]
Choonsik Lee [ Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institutes of Health, Rockville, MD, USA ]
Corresponding Author
대한방사선방어학회 [Korean Association For Radiation Protection]
설립연도
1975
분야
자연과학>기타자연과학
소개
회원 상호간의 협조와 친목을 도모함으로써 방사선방어에 관한 제반연구 및 발전에 이바지함을 물론 학술의 국제교류 및 국제학술단체와의 상호협력 증진에 기여함을 목적으로 하며, 이 목적을 달성하기 위하여 다음 각 호의 사업을 한다.
1. 방사선방어에 관한 학술연구발표회 및 강연회 등의 개최
2. 학회지 및 방사선방어에 관한 학술간행물의 발행 및 배포
3. 방사선방어에 관한 학술의 국제교류 및 협력
4. 방사선방어에 관한 국제학술자료의 조사, 수집 및 번역
5. 방사선방어에 관한 조사 및 연구용역
6. 회원의 연구활동을 위한 제반협조
7. 기타 본 학회의 목적 달성에 필요한 사항
간행물
간행물명
방사선방어학회지 [Journal of Radiation Protection and Research]