Cytotoxicity(MTT) evaluation of dental instruments made of polymers
치과용 폴리머 기구의 세포독성(MTT) 평가

첫 페이지 보기
  • 발행기관
    한국융합학회 바로가기
  • 간행물
    한국융합학회논문지 KCI 등재 바로가기
  • 통권
    제12권 제8호 (2021.08)바로가기
  • 페이지
    pp.187-195
  • 저자
    Eun-Mi Choi
  • 언어
    영어(ENG)
  • URL
    https://www.earticle.net/Article/A398785

※ 기관로그인 시 무료 이용이 가능합니다.

4,000원

원문정보

초록

영어
In order to assess the cell toxicity of 10 instruments made of polymers, the MTT assay which utilizes the L-929 cell was selected. Specimens were eluted at a temperature of 37°C for 24 hours at a rate of 4g per 20mL, RPMI 1640, and then was positively and negatively contrasted with a control test solution, in accordance with the Notification No. 2020-12 Protocols of Medical Apparatus Biological Safety from the Ministry of Drug and Food Safety. As a result of 24 hours of incubation in 37°C, 5% CO2 Incubator and assessment using an ELISA reader, the results of Intraoral camera indiciated a cellular viability of more than 70% at a 50% eluate. But, the Plastic impression tray, 3D printing tweezer, Impression disposable syringe, Dental floss holder, Hand implant scaler, Surgical retractor, Oral scanner tip, Dental mirror, and the Water pick tip all reported a cellular viability of more than 70% at a 100% eluate, which indicates that do not exhibit cytotoxicity, thus allowing it to be used in contact with the mucous membrane of the oral cavity.
한국어
최근 치과에서 사용되는 10종의 폴리머 기구에 대한 세포독성을 평가하기 위하여 L-929 세포를 이용한 MTT 시험을 시행하였다. 검체를 4g 당 20mL의 비율로 제조한 37℃의 RPMI 1640 용액에서 24시간 동안 용출한 후 식품 의약품안전처 고시 제2020-12호 의료기기 생물학적 안전에 관한 공통기준규격에 따라 검체 용출액과 공시험액, 음성 및 양성대조를 사용하여, 37℃, 5% CO2 Incubator에서 24시간 배양하여 ELISA reader로 판정한 결과, Intraoral camera는 용출물 농도 약 50%에서 약 70% 이상의 세포 생존율을 나타냈나 Plastic impression tray, 3D printing tweezer, Impression disposable syringe, Dental floss holder, Hand implant scaler, Surgical retractor, Oral scanner tip, Dental mirror, Water pick tip은 모두 용출물 농도 100%에서 70% 이상의 세포 생존율로 세포 독성을 나타내지 않아 구강점막에 직접 접촉하여 사용이 가능한 기구로 평가되었다.

목차

Abstract
요약
1. Introduction
2. Materials and Methods
2.1 Study Materials and Specimen
2.2 Preparation of Experimental Materials
2.3 Preparation of control
2.4 Experimental Apparatus
2.5 Suppliers
2.6 Experimental procedures
2.7 Evaluation of cytotoxicity
3. Results
3.1 Intraoral camera
3.2 Plastic impression tray
3.3 3D printing tweezer
3.4 Impression disposable syringe
3.5 Dental floss holder
3.6 Hand implant scaler
3.7 Surgical retractor
3.8 Oral scanner tip
3.9 Dental mirror
3.10 Water pick tip
4. Discussion
5. Conclusions
REFERENCES

키워드

치과용 폴리머 MTT 시험 세포독성시험 플라스틱 기구 치과재료 Dental polymer MTT assay Cytotoxicity test Plastic instruments Dental materials

저자

  • Eun-Mi Choi [ 최은미 | Professor, Dept. of Dental Hygiene, Kyungdong University ] Corresponding Author

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    한국융합학회 [Korea Convergence Society]
  • 설립연도
    2011
  • 분야
    복합학>학제간연구
  • 소개
    본회는 융합학문 및 융합기술을 교류를 통한 학문기술의 확대․발전․보급 및 기술개발 전략에 과학적으로 접근하여 융합학문 및 기술을 더욱 활성화하고, 회원 상호간의 정보 교류를 도모함으로써 지역과 나라발전에 기여함을 목적으로 한다.

간행물

  • 간행물명
    한국융합학회논문지 [Journal of the Korea Convergence Society]
  • 간기
    월간
  • pISSN
    2233-4890
  • 수록기간
    2010~2022
  • 십진분류
    KDC 530 DDC 620

이 권호 내 다른 논문 / 한국융합학회논문지 제12권 제8호

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.