디지털 광 조명 방식으로 제작한 임시 크라운의 세척 시간에 따른 3차원 적합도 평가
Comparison of three-dimensional adaptation as per the rinsing time of temporary crown manufactured using a digital light processing printer
Purpose: This study aimed to compare three-dimensional adaptation with the rinsing time of the temporary crown produced using the digital light processing method. Methods: The maxillary right first molar abutment was scanned with a dental scanner. A temporary crown was designed with the scanned abutment. The designed crown was made of 10 temporary crowns using a digital light processing printer. The crowns were divided into the 5-minute and 10-minute rinsing groups; 5 temporary crown washes were performed for each group. In order to obtain the internal data, each group was scanned for a temporary crown. The three-dimensional fit was measured by superimposing the scanned internal surface data and the abutment data. The average comparison of three-dimensional adaptation was analyzed using the Mann–Whitney U test. Results: The 5-minute rinsing group showed a significantly higher adaptation of 71.42±3.08 μm as compared to the 10-minute rinsing group (67.52±0.92 μm) (p<0.05). Conclusion: When making a temporary crown with a digital light processing method, a rinsing time of 10 minutes is appropriate.
목차
Abstract INTRODUCTION MATERIALS AND METHODS 1. 지대치모형 제작 및 스캔 2. 임시 크라운 제작 3. 3차원 적합도를 위한 내면 데이터 산출 및 중첩 4. 통계 분석 RESULTS 1. 세척 시간에 따른 정량적 평가 분석 결과 2. 세척 시간에 따른 정성적 평가 분석 결과 DISCUSSION CONCLUSIONS CONFLICT OF INTEREST ACKNOWLEDGEMENTS ORCID REFERENCES