Purpose: This study aimed to find out the effectiveness of gum elastic bougies for intubation in comparison to stylet according to airway type using a manikin. Methods: The study subjects were 52 paramedic students who intubated using a Macintosh laryngoscope and compared stylet and gum elastic bougie use in a 7.5 mmID endotracheal tube, on a manikin with either normal or difficult airway. Difficult airway was made Philadelphia neck collar. Collected data included intubation time, accuracy and ease of intubation, later analyzed by frequency analysis, descriptive analysis, independent t-test, chi square test, paired t-test, and McNemar test using SPSS Statistics 18.0. Results: There was a significant difference in intubation time according to intubation device and airway type (p=.000). There was no significant difference in accuracy of intubation according to intubation device or airway type (normal airway p=1.000, difficult airway p=.052). There was a significant difference in ease of intubation scale according to intubation device and airway type (p=.000, p=.000). Conclusion: Based on the speed and ease of intubation, gum elastic bougie is recommended for intubation in patients with difficult airways such as those with cervical injury.
목차
=Abstract = Ⅰ. 서론 1. 연구의 필요성 2. 연구의 목적 Ⅱ. 연구방법 1. 연구설계 2. 연구대상 3. 자료수집 방법 4. 연구 도구 및 용어의 정의 5. 분석방법 Ⅲ. 연구결과 1. 연구 대상자의 일반적 특성 2. 가설 검증 Ⅳ. 고찰 Ⅴ. 결론 ORCID ID References
키워드
Gum elastic bougieDifficult airwayManikin testParamedic students
한국응급구조학회 [The Korean Society of Emergency Medical Technology]
설립연도
1997
분야
의약학>응급의학
소개
복합 구조적인 산업사회의 발전에 따라 안전사고와 응급상황에서의 구조구급요청자들이 증가하고 있으나 우리나라의 응급의료체계는 아직 그 수준을 따라가지 못하고 있는 실정이다. 이에 우리나라의 응급의료체계를 확립하고 구조구급에 관한 기초학문의 발전에 기여하고자 학회를 창립한다.
간행물
간행물명
한국응급구조학회지(구 한국응급구조학회논문지) [The Korean Journal of Emergency Medical Services ]