Earticle

현재 위치 Home

생식선을 포함하지 않는 Chest CT촬영 시 0.25mmPb 차폐체의 생식선 차폐 유용성 연구
A Study on Shielding A study on the usefulness of gonad shielding of a 0.25mmPb shielding board in Chest CT which does not include the gonad

첫 페이지 보기
  • 발행기관
    대한안전경영과학회 바로가기
  • 간행물
    대한안전경영과학회 학술대회논문집 바로가기
  • 통권
    2014년 대한안전경영과학회 추계학술대회 (2014.11)바로가기
  • 페이지
    pp.209-214
  • 저자
    신대철, 김황우, 박소희, 육현지, 김태형, 제섭, 서선열
  • 언어
    한국어(KOR)
  • URL
    https://www.earticle.net/Article/A349039

※ 기관로그인 시 무료 이용이 가능합니다.

4,000원

원문정보

초록

영어
The number of CT gradually tends to increase, but radiation exposure includes higher exposure dose of patients than other test methods as the rate of 67% in the whole radiology tests. Exposure dose of patients has increased due to it and the second exposure has been done by scattered rays of other organs except for test sites. Especially, special shielding has not been done in gonad which is very sensitive to radiation in brain and chest CT. So this study tries to research the second exposure dose of the gonad and how to shield it in Chest CT which does not include it. It was intended for 20 male adults who are 30 years old and conduct chest CT. SIEMENS’s SOMATOM DEFINITION AS* was used as CT equipment. For the scanning conditions, The tube voltage is 120kv, the tube current is 90mAs, and the slice thickness is 3mm as the general chest CT conditions. CHIYODA TECHNOL CORPORATION’s FGD1000 was used as Glass dosimeter (PLD). A lead pad of 0.25mmPb was produced as the shielding board. For the research method, the shielding rate was compared by measuring exposure dose of the gonad before and after shielding and the usefulness of the shielding board was evaluated. The average exposure dose of symphysis pubica before shielding was 280.5μGy and the average exposure dose of coccyx was measured as 151.5μGy. The average exposure dose of symphysis pubica after shielding the gonad with a lead pad of 0.25mmPb was 42μGy and the average exposure dose of coccyx was measured as 41μGy.

목차

Abstract
1. 서론
2. 대상 및 방법
2.1 연구대상
2.2 연구 방법
3. 결과
4. 고찰
5. 결론
6. 참고문헌

키워드

exposure dose shielding shielding board chest CT

저자

  • 신대철 [ Dae-cheol Shin | 을지대학교 ]
  • 김황우 [ Hwang-woo Kim | 을지대학교 ]
  • 박소희 [ 을지대학교 ]
  • 육현지 [ 을지대학교 ]
  • 김태형 [ Tae-Hyeong Kim | 을지대학교병원 ]
  • 제섭 [ Seop Je | 을지대학교병원 ]
  • 서선열 [ Seon-yeol Seo | 을지대학교병원 ]

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    대한안전경영과학회 [Korea Safety Management & Science]
  • 설립연도
    1999
  • 분야
    공학>안전공학
  • 소개
    안전경영에 관한 학문과 기술을 발전,보급,응용하여 안전기술 및 관리기술의 진흥에 공헌하며, 재해예방을 통한 안전사회의 구현을 그 목적으로 함.

간행물

  • 간행물명
    대한안전경영과학회 학술대회논문집
  • 간기
    부정기
  • 수록기간
    1999~2022
  • 십진분류
    KDC 530 DDC 620

이 권호 내 다른 논문 / 대한안전경영과학회 학술대회논문집 2014년 대한안전경영과학회 추계학술대회

    피인용수 : 0(자료제공 : 네이버학술정보)