Earticle

현재 위치 Home

CT AAPM 팬텀에서 슬라이스 두께, 공간 분해능, 저대조도 분해능의 MATLAB을 이용한 정량적 분석 방법에 관한 연구
A Study on the Safety of Electromagnetic Wave of Medical Imaging System

첫 페이지 보기
  • 발행기관
    대한안전경영과학회 바로가기
  • 간행물
    대한안전경영과학회 학술대회논문집 바로가기
  • 통권
    2014년 대한안전경영과학회 추계학술대회 (2014.11)바로가기
  • 페이지
    pp.195-207
  • 저자
    송영우, 김시현, 안정민, 김광훈, 이채연, 서선열, 오현식
  • 언어
    한국어(KOR)
  • URL
    https://www.earticle.net/Article/A349038

※ 기관로그인 시 무료 이용이 가능합니다.

4,500원

원문정보

초록

영어
We performed the quantitative analysis using MATLAB for slice thickness, spatial resolution, and low contrast resolution with the 50 received images which have suitable judgement by scanning AAPM phantom using GE, PHILIPS, SIEMENS, and TOSHIBA. Slice thickness and spatial resolution were measured by using full width at half maximum(below FWHM). Spatial resolution was confirmed that FWHM interval more than 1.0 mm size. Low contrast resolution was measured that how close by using Roundness Index(below RI) until 6.4 mm size. The spatial resolution 9 images and low contrast resolution 10 images which have disapproved judgement were also had the quantitative analysis. The statistic analysis was judged to have statistically significant differences when p-value is less than 0.05 through SPSS statistics 19.0 and T-test (paired t-test). For slice thickness 5 mm, the average qualitative evaluation group shows 4.98 mm and quantitative evaluation group shows 5.02. For slice thickness 10 mm, the average qualitative evaluation group shows 9.98 mm and quantitative evaluation group shows 9.86. No significant differences (p=0.07, p=0.06) with 5 mm and 10 mm. It confirmed the interval for all FWHM until 1.75, 1.50, 1.25, 1.00 mm as approved images on spatial resolution ,and the average distance was 0.102 mm and the minimum distance 0.054 mm. For disapproved images, all interval was not showed under 1.00 mm. For low contrast resolution, spproved image’s RI value shows average 0.81 and minimum 0.77. The disapproved image’s RI average shows 0.70. Statiscally significant differences were presented (all p<0.05) following hole size.

목차

Abstract
1. 서론
2. 대상 및 방법
2.1 재료 및 장비
2.2 방법
3. 결과
3.1 슬라이스 두께
3.2 공간분해능
3.3 저대조도 분해능
4. 고찰
5. 결론
6. 참고문헌

키워드

slice thickness low contrast resolution spatial resolution qualitative evaluation quantitative evaluation.

저자

  • 송영우 [ Yeong-Woo Song | 을지대학교 ]
  • 김시현 [ Si-Hyun Kim | 을지대학교 ]
  • 안정민 [ Jeong-Min Ahn | 을지대학교 ]
  • 김광훈 [ Gwang-Hoon Kim | 을지대학교 ]
  • 이채연 [ Chae-Yeon Lee | 을지대학교 ]
  • 서선열 [ Sun-Youl Seo | 을지대학교 ]
  • 오현식 [ Hyun-Sik Oh | 서울 삼성의료원 ]

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    대한안전경영과학회 [Korea Safety Management & Science]
  • 설립연도
    1999
  • 분야
    공학>안전공학
  • 소개
    안전경영에 관한 학문과 기술을 발전,보급,응용하여 안전기술 및 관리기술의 진흥에 공헌하며, 재해예방을 통한 안전사회의 구현을 그 목적으로 함.

간행물

  • 간행물명
    대한안전경영과학회 학술대회논문집
  • 간기
    부정기
  • 수록기간
    1999~2022
  • 십진분류
    KDC 530 DDC 620

이 권호 내 다른 논문 / 대한안전경영과학회 학술대회논문집 2014년 대한안전경영과학회 추계학술대회

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장