Earticle

현재 위치 Home

Poster Presentation : Stem Cells

Identification of a Technique Sorting Effectively Spermatogonial Stem Cells from Mouse Testes

첫 페이지 보기
  • 발행기관
    한국동물생명공학회(구 한국동물번식학회) 바로가기
  • 간행물
    발생공학 국제심포지엄 및 학술대회 바로가기
  • 통권
    2018년 한국동물번식학회, 한국수정란이식학회 공동학술대회 (2018.06)바로가기
  • 페이지
    pp.131-132
  • 저자
    Na Rae Han, Hye Jin Park, Hyun Lee, Seung Tae Lee
  • 언어
    영어(ENG)
  • URL
    https://www.earticle.net/Article/A347508

원문정보

초록

영어
Spermatogonial stem cells (SSCs) can produce sperms transferring genetic information into the next generation in seminiferous tubule of testes. Accordingly, an efficient isolation technique of SSCs with extremely low numbers from testes is required for successful downstream researches related to maintenance, differentiation and cryopreservation of SSCs. To date, a variety of isolation techniques in a variety of species have been used for retrieving SSCs from testicular tissue. However, comparison of their efficiency has been not revealed clearly. Accordingly, among isolation methods described previously, we tried to elucidate a technique showing the best isolation efficiency in the retrieval of SSCs from testes derived from mice. For these, SSCs were isolated from mouse testis as follows: differential plating (DP), EpCAM, Thy1 or GFRα1 antibody-based magnetic-activating cell sorting (MACS) post-DP, EpCAM, Thy1 or GFR α1 antibody-based MACS, EpCAM, Thy1 or GFRα1 antibody-based MACS post-MACS based on GFRα1 antibody (double MACS for positive selection), and CD34 or α-SMA antibody-based MACS post-MACS based on GFRα1 antibody (double MACS for negative selection). Subsequently, SSCs isolated from each method were stained by alkaline phosphatase (AP) staining and percentage of AP positive SSCs was compared to find an optimal method among isolation method candidates. As the results, SSCs isolated by DP for 8 h showed numerically the highest percentage of AP positive SSCs. In case of MACS post-DP, SSCs isolated by MACS based on Thy1 antibody post-DP (MACSThy1 post-DP) revealed numerically higher percentage of AP positive cells than those on EpCAM and GFRα1 antibodies post-DP. Moreover, numerically the highest percentage of AP positive SSCs was detected when SSCs were isolated from mouse testis by MACS based on GFRα1 (MACSGFRα1) compared to EpCAM and Thy1 antibodies. In case of double MACS for positive selection, the usage of EpCAM antibody in the second MACS post-GFRα1 antibody-based MACS (double MACSGFRα1/EpCAM) showed numerically the highest percentage of AP positive SSCs compared to Thy1 and GFRα1 antibodies. On the other hands, after GFRα1 antibody-based MACS sorting, the usage of α-SMA antibody in the second MACS (double MACSGFRα1/α-SMA) for negative selection showed numerically higher percentage of AP positive SSCs than CD34 antibody. The subsequent comparison of isolation efficiency derived from each method demonstrated that MACSGFRα1 and double MACSGFRα1/EpCAM resulted in significantly the best isolation efficiency. Accordingly, we could elucidate that MACSGFRα1 and double MACSGFRα1/EpCAM were techniques sorting effectively SSCs from mouse testes.

저자

  • Na Rae Han [ Department of Animal Life Science, Kangwon National University, Chuncheon 24341, Korea ]
  • Hye Jin Park [ Department of Animal Life Science, Kangwon National University, Chuncheon 24341, Korea ]
  • Hyun Lee [ Department of Animal Life Science, Kangwon National University, Chuncheon 24341, Korea ]
  • Seung Tae Lee [ Department of Animal Life Science, Department of Applied Animal Science, Kangwon National University, Chuncheon 24341, Korea ]

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    한국동물생명공학회(구 한국동물번식학회) [The Korean Society of Animal Reproduction and Biotechnology]
  • 설립연도
    1976
  • 분야
    농수해양>축산학
  • 소개
    동물번식생리학, 동물생명공학, 수의학, 인공수정 및 수정란이식을 이용한 동물개량에 관한 이론과 기술의 발전을 통해 학계, 연구계, 산업계 및 양축가 상호간의 협력을 도모함으로써 동물과학발전 및 사회일반의 이익에 기여 한다는 목적을 위해 노력해 나가겠습니다.

간행물

  • 간행물명
    발생공학 국제심포지엄 및 학술대회 [International Symposium on Developmental Biotechnology]
  • 간기
    연간
  • 수록기간
    2004~2018
  • 십진분류
    KDC 527 DDC 636

이 권호 내 다른 논문 / 발생공학 국제심포지엄 및 학술대회 2018년 한국동물번식학회, 한국수정란이식학회 공동학술대회

    피인용수 : 0건 (자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장