Earticle

현재 위치 Home

Discrepancies in Dose-volume Histograms Generated from Different Treatment Planning Systems

첫 페이지 보기
  • 발행기관
    대한방사선방어학회 바로가기
  • 간행물
    방사선방어학회지 KCI 등재 바로가기
  • 통권
    VOLUME 43 NUMBER 2 (2018.06)바로가기
  • 페이지
    pp.59-65
  • 저자
    Jung-in Kim, Ji Hye Han, Chang Heon Choi, Hyun Joon An, Hong-Gyun Wu, Jong Min Park
  • 언어
    영어(ENG)
  • URL
    https://www.earticle.net/Article/A332908

원문정보

초록

영어
Background: We analyzed changes in the doses, structure volumes, and dose-volume histograms (DVHs) when data were transferred from one commercial treatment planning system (TPS) to another commercial TPS. Materials and Methods: A total of 22 volumetric modulated arc therapy (VMAT) plans for nasopharyngeal cancer were generated with the Eclipse system using 6-MV photon beams. The computed tomography (CT) images, dose distributions, and structure information, including the planning target volume (PTV) and organs at risk (OARs), were transferred from the Eclipse to the MRIdian system in digital imaging and communications in medicine (DICOM) format. Thereafter, DVHs of the OARs and PTVs were generated in the MRIdian system. The structure volumes, dose distributions, and DVHs were compared between the MRIdian and Eclipse systems. Results and Discussion: The dose differences between the two systems were negligible (average matching ratio for every voxel with a 0.1% dose difference criterion = 100.0 ± 0.0%). However, the structure volumes significantly differed between the MRIdian and Eclipse systems (volume differences of 743.21 ± 461.91% for the optic chiasm and 8.98 ± 1.98% for the PTV). Compared to the Eclipse system, the MRIdian system generally overestimated the structure volumes (all, p < 0.001). The DVHs that were plotted using the relative structure volumes exhibited small differences between the MRIdian and Eclipse systems. In contrast, the DVHs that were plotted using the absolute structure volumes showed large differences between the two TPSs. Conclusion: DVH interpretation between two TPSs should be performed using DVHs plotted with the absolute dose and absolute volume, rather than the relative values.

목차

ABSTRACT
 Introduction
 Materials and Methods
  1. Patient data and planning
  2. Data transfer from the Eclipse to the MRIdian system
  3. Evaluation of doses, volumes, and dose-volume histograms
 Results and Discussion
  1. Dose differences
  2. Volume differences
  3. Dose-volume histogram differences
 Conclusion
 Acknowledgements
 References

키워드

Dose-volumetric parameter Treatment planning system Volumetric-modulated arc therapy Calculation algorithms

저자

  • Jung-in Kim [ Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea, Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea, Biomedical Research Institute, Seoul National University College of Medicine, Seoul, Korea ]
  • Ji Hye Han [ Department of Physics, Ewha Womans University, Seoul, Korea ]
  • Chang Heon Choi [ Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea, Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea, Biomedical Research Institute, Seoul National University College of Medicine, Seoul, Korea ]
  • Hyun Joon An [ Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea, Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea, Biomedical Research Institute, Seoul National University College of Medicine, Seoul, Korea ]
  • Hong-Gyun Wu [ Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea, Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea, Biomedical Research Institute, Seoul National University College of Medicine, Seoul, Korea, Department of Radiation Oncology, Seoul National University College of Medicine, Seoul, Korea ]
  • Jong Min Park [ Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea, Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea, Biomedical Research Institute, Seoul National University College of Medicine, Seoul, Korea, Robotics Research Laboratory for Extreme Environments, Advanced Institutes of Convergence Technology, Suwon, Korea ] Corresponding author

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    대한방사선방어학회 [Korean Association For Radiation Protection]
  • 설립연도
    1975
  • 분야
    자연과학>기타자연과학
  • 소개
    회원 상호간의 협조와 친목을 도모함으로써 방사선방어에 관한 제반연구 및 발전에 이바지함을 물론 학술의 국제교류 및 국제학술단체와의 상호협력 증진에 기여함을 목적으로 하며, 이 목적을 달성하기 위하여 다음 각 호의 사업을 한다. 1. 방사선방어에 관한 학술연구발표회 및 강연회 등의 개최 2. 학회지 및 방사선방어에 관한 학술간행물의 발행 및 배포 3. 방사선방어에 관한 학술의 국제교류 및 협력 4. 방사선방어에 관한 국제학술자료의 조사, 수집 및 번역 5. 방사선방어에 관한 조사 및 연구용역 6. 회원의 연구활동을 위한 제반협조 7. 기타 본 학회의 목적 달성에 필요한 사항

간행물

  • 간행물명
    방사선방어학회지 [Journal of Radiation Protection and Research]
  • 간기
    계간
  • pISSN
    2508-1888
  • 수록기간
    1976~2026
  • 등재여부
    KCI 등재,SCOPUS
  • 십진분류
    KDC 559 DDC 629

이 권호 내 다른 논문 / 방사선방어학회지 VOLUME 43 NUMBER 2

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장