Background: Different cases exist in the measurement of thyroid radiobioassays owing to the individual characteristics of the subjects, especially the potential variation in the counting efficiency. An In situ Object Counting System (ISOCS) was developed to perform an efficiency calibration based on the Monte Carlo calculation, as an alternative to conventional calibration methods. The purpose of this study is to evaluate the applicability of ISOCS to thyroid radiobioassays by comparison with a conventional thyroid monitoring system. Materials and Methods: The efficiency calibration of a portable high-purity germanium (HPGe) detector was performed using ISOCS software. In contrast, the conventional efficiency calibration, which needed a radioactive material, was applied to a scintillator-based thyroid monitor. Four radioiodine samples that contained 125I and 131I in both aqueous solution and gel forms were measured to evaluate radioactivity in the thyroid. ANSI/HPS N13.30 performance criteria, which included the relative bias, relative precision, and root-mean-squared error, were applied to evaluate the performance of the measurement system. Results and Discussion: The portable HPGe detector could measure both radioiodines with ISOCS but the thyroid monitor could not measure 125I because of the limited energy resolution of the NaI(Tl) scintillator. The 131I results from both detectors agreed to within 5% with the certified results. Moreover, the 125I results from the portable HPGe detector agreed to within 10% with the certified results. All measurement results complied with the ANSI/HPS N13.30 performance criteria. Conclusion: The results of the intercomparison program indicated the feasibility of applying ISOCS software to direct thyroid radiobioassays. The portable HPGe detector with ISOCS software can provide the convenience of efficiency calibration and higher energy resolution for identifying photopeaks, compared with a conventional thyroid monitor with a NaI(Tl) scintillator. The application of ISOCS software in a radiation emergency can improve the response in terms of internal contamination monitoring.
목차
ABSTRACT Introduction Materials and Methods 1. LLNL Thyroid Radioiodine Intercomparison program 2. Radioiodine samples and detection system 3. Calculation and evaluation techniques Results and Discussion Conclusion Acknowledgements References
키워드
Radiation emergencyRadioactivityRadioiodineMonte Carlo methodRadiobioassay
저자
MinSeok Park [ National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, Seoul, Korea ]
Tae-Eun Kwon [ National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, Seoul, Korea ]
Min Jung Pak [ National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, Seoul, Korea ]
Se-Young Park [ National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, Seoul, Korea ]
Wi-Ho Ha [ National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, Seoul, Korea ]
Corresponding author
Young-Woo Jin [ National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, Seoul, Korea ]
대한방사선방어학회 [Korean Association For Radiation Protection]
설립연도
1975
분야
자연과학>기타자연과학
소개
회원 상호간의 협조와 친목을 도모함으로써 방사선방어에 관한 제반연구 및 발전에 이바지함을 물론 학술의 국제교류 및 국제학술단체와의 상호협력 증진에 기여함을 목적으로 하며, 이 목적을 달성하기 위하여 다음 각 호의 사업을 한다.
1. 방사선방어에 관한 학술연구발표회 및 강연회 등의 개최
2. 학회지 및 방사선방어에 관한 학술간행물의 발행 및 배포
3. 방사선방어에 관한 학술의 국제교류 및 협력
4. 방사선방어에 관한 국제학술자료의 조사, 수집 및 번역
5. 방사선방어에 관한 조사 및 연구용역
6. 회원의 연구활동을 위한 제반협조
7. 기타 본 학회의 목적 달성에 필요한 사항
간행물
간행물명
방사선방어학회지 [Journal of Radiation Protection and Research]