Earticle

현재 위치 Home

Performance Analysis of the DigSILENT PV Model Connected to a Modelled Malaysian Distribution Network

첫 페이지 보기
  • 발행기관
    보안공학연구지원센터(IJCA) 바로가기
  • 간행물
    International Journal of Control and Automation SCOPUS 바로가기
  • 통권
    Vol.9 No.12 (2016.12)바로가기
  • 페이지
    pp.75-88
  • 저자
    Parthiban Perumal, Agileswari K. Ramasamy, Au Mau Teng
  • 언어
    영어(ENG)
  • URL
    https://www.earticle.net/Article/A294942

※ 원문제공기관과의 협약기간이 종료되어 열람이 제한될 수 있습니다.

원문정보

초록

영어
The global growth of Photovoltaic (PV) is remarkable with a total of 135 GW in 2013 from 10GW in 2007. Operation of PV has changed from standalone to grid-connected which brings several challenges. This sudden spike in PV capacity is due to the reduced cost of PV modules over five times in last six years and followed by advancements in PV inverter technologies. Integration of distributed generation alters the unidirectional power system to bidirectional and alongside present’s issues such as overvoltage on distribution feeders, overloading of feeders, and undesired exchange of reactive power. Traditional methods that are in practice to control the voltage and reactive power is by controlling the transformer tap changer and using capacitor banks. Volt-VAr control (VVC) activities by traditional methods are no longer appropriate due to intermittency solar irradiation caused by cloud transients. Modern PV inverter has the capabilities to mitigate voltage related issues when they are allowed to operate at power factor other than unity as stated in the IEEE1547-a. Germany and Spain are the pioneer countries in adopting ‘smart’ inverter operation in accordance with their countries interconnection grid guidelines. Similar operation of PV inverters for Malaysian scenario is prohibited as the current guideline does not allow the participation of PV inverters in voltage control activities. Therefore it is essential to allow the operation of smart inverter for Malaysian scenario, as the number of grid connected PV system is on the rise. This paper extensively analyses the performance of the DigSILENT’s PV model control aspects in terms of active power reduction and dynamic voltage support in a test network and validation of static voltage support on modelled Malaysian distribution network according to the new German Grid Code.

목차

Abstract
 1. Introduction
 2. Review of Grid Interconnection Technical Guidelines
 4. Static Voltage Support on Modelled Malaysian High Density Commercial Network
 5. Results
 6. Future Works
 7. Conclusion
 References

저자

  • Parthiban Perumal [ College of Engineering, Universiti Tenaga Nasional, Selangor Malaysia ]
  • Agileswari K. Ramasamy [ College of Engineering, Universiti Tenaga Nasional, Selangor Malaysia ]
  • Au Mau Teng [ College of Engineering, Universiti Tenaga Nasional, Selangor Malaysia ]

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    보안공학연구지원센터(IJCA) [Science & Engineering Research Support Center, Republic of Korea(IJCA)]
  • 설립연도
    2006
  • 분야
    공학>컴퓨터학
  • 소개
    1. 보안공학에 대한 각종 조사 및 연구 2. 보안공학에 대한 응용기술 연구 및 발표 3. 보안공학에 관한 각종 학술 발표회 및 전시회 개최 4. 보안공학 기술의 상호 협조 및 정보교환 5. 보안공학에 관한 표준화 사업 및 규격의 제정 6. 보안공학에 관한 산학연 협동의 증진 7. 국제적 학술 교류 및 기술 협력 8. 보안공학에 관한 논문지 발간 9. 기타 본 회 목적 달성에 필요한 사업

간행물

  • 간행물명
    International Journal of Control and Automation
  • 간기
    월간
  • pISSN
    2005-4297
  • 수록기간
    2008~2016
  • 십진분류
    KDC 505 DDC 605

이 권호 내 다른 논문 / International Journal of Control and Automation Vol.9 No.12

    피인용수 : 0건 (자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장