Earticle

현재 위치 Home

Evaluation of Gamma-Ray Attenuation Parameters for Some Materials

첫 페이지 보기
  • 발행기관
    보안공학연구지원센터(IJHIT) 바로가기
  • 간행물
    International Journal of Hybrid Information Technology 바로가기
  • 통권
    Vol.9 No.11 (2016.11)바로가기
  • 페이지
    pp.437-446
  • 저자
    Amal A. El- Sawy
  • 언어
    영어(ENG)
  • URL
    https://www.earticle.net/Article/A291757

※ 원문제공기관과의 협약기간이 종료되어 열람이 제한될 수 있습니다.

원문정보

초록

영어
In the present study, the linear attenuation coefficient and mass attenuation coefficient have been calculated at energy range of 0.8MeV, 1MeV, 3Mev, 5MeV and 7MeV. The mass attenuation Coefficient μm has been calculated analytically for Iron material Fe (ρ= 7.87 g/cm3) and developed material lead Pb (ρ= 11.3 g/cm3) at photon energies [0.8 MeV to 7 MeV] using X-Com computer code. The obtained results were compared with the calculated values. The linear attenuation Coefficient μ has been calculated, its variations with photon energy were plotting. The Comparison between two materials Iron and Lead were also studied. The obtained result shows that μ and μm depends on the photon energy, density of the materials and atomic number. From this study we notice that the values of μm and μ of Lead material is greater than Iron material and also the values are decreasing with increasing the photon energy. The half value layer (HVL) and tenth value layer (TVL) of two studied materials were calculated at photon energy range of 0.8 MeV, 1MeV, 5MeV and 7MeV. The relation between this equation Ln (Io/I) and the thickness of material were calculated, so the curves show that the relation of Ln (Io/I) of Iron and Lead materials is increasing with the increasing of material thickness and the relation gives the straight line, also the comparison of this relation for Lead material is higher than Iron material. This study can also be utilized to improve the effectiveness of radiation shielding by using the developed shielding material.

목차

Abstract
 1. Introduction
 2. Theoretical Background
  2.1 Attenuation of Radiation in Matter
  2.2 Calculation of Mass Attenuation Coefficient
  2.3 Calculation of HVL and TVL
 3. Method of Calculation
  3.1 Mathematical Model
  3.2 Calculation of Linear Attenuation Coefficient and Mass Attenuation Coefficient
 4. Results and Discussion
  4.1 Linear Attenuation Coefficient (μ)
  4.2 Mass Attenuation Coefficient (μm)
  4.3 Half Value Layer (HVL), Tenth Value Layer (TVL) and Ln (Io/I)
 5. Conclusion
 References

저자

  • Amal A. El- Sawy [ Radiation Safety Department, Egyptian Nuclear and Radiological Regulatory Authority (ENRRA), Cairo- Egypt ]

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    보안공학연구지원센터(IJHIT) [Science & Engineering Research Support Center, Republic of Korea(IJHIT)]
  • 설립연도
    2006
  • 분야
    공학>컴퓨터학
  • 소개
    1. 보안공학에 대한 각종 조사 및 연구 2. 보안공학에 대한 응용기술 연구 및 발표 3. 보안공학에 관한 각종 학술 발표회 및 전시회 개최 4. 보안공학 기술의 상호 협조 및 정보교환 5. 보안공학에 관한 표준화 사업 및 규격의 제정 6. 보안공학에 관한 산학연 협동의 증진 7. 국제적 학술 교류 및 기술 협력 8. 보안공학에 관한 논문지 발간 9. 기타 본 회 목적 달성에 필요한 사업

간행물

  • 간행물명
    International Journal of Hybrid Information Technology
  • 간기
    격월간
  • pISSN
    1738-9968
  • 수록기간
    2008~2016
  • 십진분류
    KDC 505 DDC 605

이 권호 내 다른 논문 / International Journal of Hybrid Information Technology Vol.9 No.11

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장