Earticle

현재 위치 Home

Effects of cyclic mean pressure of helium gas on performance of integral crank driven stirling cryocooler

첫 페이지 보기
  • 발행기관
    한국초전도저온학회 (구 한국초전도저온공학회) 바로가기
  • 간행물
    한국초전도·저온논문지 (구 한국초전도저온공학회논문지) KCI 등재 바로가기
  • 통권
    Vol.18 No.3 (2016.09)바로가기
  • 페이지
    pp.30-34
  • 저자
    Yong-Ju Hong, Junseok Ko, Hyo-Bong Kim, Seong-Je Park
  • 언어
    영어(ENG)
  • URL
    https://www.earticle.net/Article/A286962

※ 기관로그인 시 무료 이용이 가능합니다.
※ 학술발표대회집, 워크숍 자료집 중 4페이지 이내 논문은 '요약'만 제공되는 경우가 있으니, 구매 전에 간행물명, 페이지 수 확인 부탁 드립니다.

4,000원

원문정보

초록

영어
An integral crank driven Stirling cryocooler is solidly based on concepts of direct IR detector mounting on the cryocooler’s cold finger, and the integral construction of the cryocooler and Dewar envelope. Performance factors of the cryocooler depend on operating conditions of the cryocooler such as a cyclic mean pressure of the working fluid, a rotational speed of driving mechanism, a thermal environment, a targeted operation temperature and etc.. At given charging condition of helium gas, the cyclic mean pressure of helium gas in the cryocooler changes with temperatures of the cold end and the environment. In this study, effects of the cyclic mean pressure of helium gas on performances of the Stirling cryocooler were investigated by numerical analyses using the Sage software. The simulation model takes into account thermodynamic losses due to an inefficiency of regenerator, a pressure drop, a shuttle heat transfer and solid conductions. Simulations are performed for the performance variation according to the cyclic mean pressure induced by the temperature of the cold end and the environment. This paper presents P-V works in the compression and expansion space, cooling capacity, contribution of losses in the expansion space.

목차

Abstract
 1. INTRODUCTION
 2. SIMULATION MODEL OF A STIRLINGCRYOCOOLER
 3. SIMULATION RESULTS
  3.1. Case for Given Cyclic Mean Pressure
  3.2. Case for Given Condition of Charging Pressure with Variation of Environmental Temperature
  3.3. Case for Given Condition of Charging Pressure with Variation of Cold End Temperature
 4. SUMMARY
 ACKNOWLEDGMENT
 REFERENCES

키워드

Stirling cryocooler Cyclic mean pressure Cooling capacity Loss

저자

  • Yong-Ju Hong [ Korea Institute of Machinery & Materials ] Corresponding author
  • Junseok Ko [ Korea Institute of Machinery & Materials ]
  • Hyo-Bong Kim [ Korea Institute of Machinery & Materials ]
  • Seong-Je Park [ Korea Institute of Machinery & Materials ]

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    한국초전도저온학회 (구 한국초전도저온공학회) [The Korean Society of Superconductivity and Cryogenics (KSSC)]
  • 설립연도
    1998
  • 분야
    공학>전기공학
  • 소개
    21세기 핵심기술인 초전도공학과 저온공학분야의 기술 수준을 향상시키고, 선진 외국의 관련 학회와의 국제 교류 뿐만 아니라 이 분야에서 산.학.연의 학술활동 및 기술교류의 구심점으로의 그 역할을 성실히 수행하고자 한다.

간행물

  • 간행물명
    한국초전도·저온논문지 (구 한국초전도저온공학회논문지) [Progress in Superconductivity and Cryogenics]
  • 간기
    계간
  • pISSN
    1229-3008
  • eISSN
    2287-6251
  • 수록기간
    1999~2026
  • 등재여부
    KCI 등재,SCOPUS
  • 십진분류
    KDC 427 DDC 537

이 권호 내 다른 논문 / 한국초전도·저온논문지 (구 한국초전도저온공학회논문지) Vol.18 No.3

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장