Earticle

현재 위치 Home

PAPER

Preliminary Research of CZT Based PET System Development in KAERI

첫 페이지 보기
  • 발행기관
    대한방사선방어학회 바로가기
  • 간행물
    방사선방어학회지 KCI 등재 바로가기
  • 통권
    VOLUME 41 NUMBER 2 (2016.06)바로가기
  • 페이지
    pp.81-86
  • 저자
    Woo Jin Jo, Manhee Jeong, Han Soo Kim, Sang Yeol Kim, Jang Ho Ha
  • 언어
    영어(ENG)
  • URL
    https://www.earticle.net/Article/A278195

원문정보

초록

영어
Background: For positron emission tomography (PET) application, cadmium zinc telluride (CZT) has been investigated by several institutes to replace detectors from a conventional system using photomultipliers or Silicon-photomultipliers (SiPMs). The spatial and energy resolution in using CZT can be superior to current scintillator-based state-of-the-art PET detectors. CZT has been under development for several years at the Korea Atomic Energy Research Institute (KAERI) to provide a high performance gamma ray detection, which needs a single crystallinity, a good uniformity, a high stopping power, and a wide band gap. Materials and Methods: Before applying our own grown CZT detectors in the prototype PET system, we investigated preliminary research with a developed discrete type data acquisition (DAQ) system for coincident events at 128 anode pixels and two common cathodes of two CZT detectors from Redlen. Each detector has a 19.4×19.4×6 mm3 volume size with a 2.2 mm anode pixel pitch. Discrete amplifiers consist of a preamplifier with a gain of 8 mV·fC-1 and noise of 55 equivalent noise charge (ENC), a CR-RC4 shaping amplifier with a 5 μs peak time, and an analog-to-digital converter (ADC) driver. The DAQ system has 65 mega-sample per second flash ADC, a self and external trigger, and a USB 3.0 interface. Results and Discussion: Characteristics such as the current-to-voltage curve, energy resolution, and electron mobility life-time products for CZT detectors are investigated. In addition, preliminary results of gamma ray imaging using 511 keV of a 22Na gamma ray source were obtained. Conclusion: In this study, the DAQ system with a CZT radiation sensor was successfully developed and a PET image was acquired by two sets of the developed DAQ system.

목차

ABSTRACT
 1. INTRODUCTION2
 2. MATERIALS AND METHODS
  2.1 CZT radiation sensor module
  2.2 Development of data acquisition (DAQ) system
  2.3 PET image acquisition
 3. Results and Discussion
  3.1 Characteristics of CZT radiation sensor
  3.2 Performance of the developed amplifier modules
  3.3 PET image acquisition
 4. CONCLUSION
 REFERENCES

키워드

PET CZT Room-temperature semiconductor radiation detector DAQ

저자

  • Woo Jin Jo [ Advanced Radiation Detection Instrument & Sensor Lab., Korea Atomic Energy Research Institute, Jeongeup, Republic of Korea ]
  • Manhee Jeong [ Advanced Radiation Detection Instrument & Sensor Lab., Korea Atomic Energy Research Institute, Jeongeup, Republic of Korea ]
  • Han Soo Kim [ Advanced Radiation Detection Instrument & Sensor Lab., Korea Atomic Energy Research Institute, Jeongeup, Republic of Korea ]
  • Sang Yeol Kim [ Notice Co., Ltd., Anyang, Republic of Korea ]
  • Jang Ho Ha [ Advanced Radiation Detection Instrument & Sensor Lab., Korea Atomic Energy Research Institute, Jeongeup, Republic of Korea ] Corresponding author

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    대한방사선방어학회 [Korean Association For Radiation Protection]
  • 설립연도
    1975
  • 분야
    자연과학>기타자연과학
  • 소개
    회원 상호간의 협조와 친목을 도모함으로써 방사선방어에 관한 제반연구 및 발전에 이바지함을 물론 학술의 국제교류 및 국제학술단체와의 상호협력 증진에 기여함을 목적으로 하며, 이 목적을 달성하기 위하여 다음 각 호의 사업을 한다. 1. 방사선방어에 관한 학술연구발표회 및 강연회 등의 개최 2. 학회지 및 방사선방어에 관한 학술간행물의 발행 및 배포 3. 방사선방어에 관한 학술의 국제교류 및 협력 4. 방사선방어에 관한 국제학술자료의 조사, 수집 및 번역 5. 방사선방어에 관한 조사 및 연구용역 6. 회원의 연구활동을 위한 제반협조 7. 기타 본 학회의 목적 달성에 필요한 사항

간행물

  • 간행물명
    방사선방어학회지 [Journal of Radiation Protection and Research]
  • 간기
    계간
  • pISSN
    2508-1888
  • 수록기간
    1976~2026
  • 등재여부
    KCI 등재,SCOPUS
  • 십진분류
    KDC 559 DDC 629

이 권호 내 다른 논문 / 방사선방어학회지 VOLUME 41 NUMBER 2

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장