Flexible AC Transmission System (FACTS), under different conditions, are being incorporated in a power system for the improvement of active power flow along with voltage at each bus. Among the many FACTS devices, Interline Power Flow Controller (IPFC) is one of its kind, that has the capability of controlling multi-transmission systems. In this paper, an Improved Power Injection Model (IPIM) of Interline Power Flow Controller (IPFC) has been introduced. This model was included to Newton-Raphson (NR) method of load flow solution. The proposed model is tested on the standard test systems. The results of standard 5-bus system, IEEE-14 bus system is presented for the purpose of demonstration.
목차
Abstract 1. Introduction 2. Improved Steady-State Model of Interline Power Flow Controller 2.1. Basic Load Flow Equations 2.2. Improved Steady state model of Interline Power Flow Controller 2.3. Modified Jacobian equations of Newton-Raphson Power Flow solution 3. Proposed Algorithm 4. Simulation Results 4.1. Standard 5-Bus system 4.2. IEEE-14 Bus System 5. Conclusion Acknowledgment References