Earticle

현재 위치 Home

Analysis of Electromagnetic Immunity Experiment for Field Installation of Intelligent Equipment in Substation

첫 페이지 보기
  • 발행기관
    보안공학연구지원센터(IJSIP) 바로가기
  • 간행물
    International Journal of Signal Processing, Image Processing and Pattern Recognition 바로가기
  • 통권
    Vol.9 No.1 (2016.01)바로가기
  • 페이지
    pp.21-32
  • 저자
    Ji Jianfei, Wang Lihui, Yuan Yubo, Yang Yifei
  • 언어
    영어(ENG)
  • URL
    https://www.earticle.net/Article/A270073

※ 원문제공기관과의 협약기간이 종료되어 열람이 제한될 수 있습니다.

원문정보

초록

영어
With the increase of voltage level and more and more secondary devices are located in field, the secondary circuit of substation is in a strong electromagnetic environment. Because the secondary circuit is affected by the interference of switch operations, there are many trip accidents happened in substations without any fault in recently years, which constitutes a serious threat to the power network and harms the safe operation of the electric power system. It is of great theoretical significance and practical value to study the Electromagnetic Compatibility problem of the transformer substations substation secondary circuit. In this paper, the abnormal phenomenon of one 110kV intelligent substation merging unit is described. And the reason of the abnormal phenomenon is analyzed. Firstly, the Electromagnetic Compatibility experiments specified by the IEC61000-4 standard are carried out. Furthermore, to verify the anti–interference performance of the merging unit, the Electromagnetic Compatibility experiments above the standard are carried out. The structure of merging unit is improved until the merging unit operates normally. Secondly, to quantitatively analyze the disturbance strength, the electromagnetic disturbance signal is recorded, and the characteristics of amplitude and time-frequency of the recorded signal are analyzed. Thirdly, the characteristics of the logged signal are compared to the IEC61000-4 standard. Finally, this paper puts forward some suggestions about improving the Electromagnetic Compatibility performance of merging unit.

목차

Abstract
 1. Introduction
 2. Background
 3. Processing Steps
  3.1. First Step
  3.2. Second Step
  3.3. Third Step
  3.4. Forth Step
 4. Conclusion and Suggestion
  4.1. Conclusions
  4.2. Suggestions
 References

키워드

Intelligent substation Field installation Electromagnetic transient disturbance

저자

  • Ji Jianfei [ Jiangsu Electric Power Research Institute Co., Ltd, Nanjing, China ]
  • Wang Lihui [ School of Instrument Science and Engineering, Southeast University, Nanjing, China ]
  • Yuan Yubo [ Jiangsu Electric Power Research Institute Co., Ltd, Nanjing, China ]
  • Yang Yifei [ Department of Automation, Nanjing University of Science and Technology, Nanjing, China ]

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    보안공학연구지원센터(IJSIP) [Science & Engineering Research Support Center, Republic of Korea(IJSIP)]
  • 설립연도
    2006
  • 분야
    공학>컴퓨터학
  • 소개
    1. 보안공학에 대한 각종 조사 및 연구 2. 보안공학에 대한 응용기술 연구 및 발표 3. 보안공학에 관한 각종 학술 발표회 및 전시회 개최 4. 보안공학 기술의 상호 협조 및 정보교환 5. 보안공학에 관한 표준화 사업 및 규격의 제정 6. 보안공학에 관한 산학연 협동의 증진 7. 국제적 학술 교류 및 기술 협력 8. 보안공학에 관한 논문지 발간 9. 기타 본 회 목적 달성에 필요한 사업

간행물

  • 간행물명
    International Journal of Signal Processing, Image Processing and Pattern Recognition
  • 간기
    격월간
  • pISSN
    2005-4254
  • 수록기간
    2008~2016
  • 십진분류
    KDC 505 DDC 605

이 권호 내 다른 논문 / International Journal of Signal Processing, Image Processing and Pattern Recognition Vol.9 No.1

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장