We present in this report a mixed DNA profile detected in a case where the deceased had received a blood transfusion. The deceased was a 58-year old female who was complicated with aplastic anemia after the orthopedic surgery. To determine the exact cause of her death, autopsy with postmortem examination was performed and identified the DNA profile from the collected blood, vaginal fluid, and heart tissue. The results of our study showed that the autosomal STR genotypes of the donor has influence on the STR genotypes of the recipient in the blood and vaginal swab samples. For conformation, the ratio of DNA using Quantifier ® DUO DNA Quantification kit was also examined. Through these results we suggest that checking whether or not those involved in an incident received a transfusion before the DNA analysis is an essential process in obtaining an accurate interpretation and conclusion.
한국어
본 논문에서는 수혈을 받은 변사자로부터 혼합 DNA 프로파일이 검출된 사례에 대해 보고하고 자 한다. 변사자는 58세 여성으로 수술 후 재생불량빈혈이 합병되어 사망에 이르렀고 사인 규명을 위해 부검이 시행되었으며 사후검사의 일환으로 질 내용물에 대한 검사, 수혈치료를 받았던 점을 고려하여 혈 액 및 장기조직으로 DNA형 분석이 시행되었다. 분석결과, 혈액 및 질 내용물 시료에서 혈액 공여자의 상염색체 STR DNA형이 수혈자의 상염색체 STR DNA형에 영향을 끼친다는 것을 관찰하였다. 또한, 검 증을 위하여 Quantifier® DUO DNA Quantification kit를 이용하여 수혈자의 시료에 포함된 공여자의 DNA 비율을 분석하였다. 본 결과를 통해 DNA 감식 전에 사건 관련자들의 수혈 여부를 인지하는 것이 혼합 DNA형 분석에 있어서 정확한 해석과 결론을 얻기 위한 필수적인 과정임을 제시하고자 한다.
목차
요약 Abstract 서론 재료 및 방법 1. 사건의 개요 2. 변사자의 시료 채취 및 혈흔 예비검사 3. DNA 추출 및 정량 4. 염색체 증폭 및 유전자형 분석 결과 및 고찰 1. 혈흔검사 및 DNA 정량 2. 상염색체 STR 증폭 3. Y 염색체 증폭 결론 감사의 말 참고문헌
키워드
수혈혼합 DNA 프로파일공여자 DNA 비율Quantifier® DUO DNA Quantification kitBlood transfusionMixed DNA profileQuantifier® DUO DNA Quantification kitThe ratio of donor’s DNA
저자
정주연 [ Ju Yeon Jung | 국립과학수사연구원 서울과학수사연구소 유전자분석과 ]
박소형 [ So Hyung Park | 국립과학수사연구원 중앙법의학센터 ]
박선화 [ Sun Wha Park | 국립과학수사연구원 서울과학수사연구소 유전자분석과 ]
박문희 [ Moon Hee Park | 국립과학수사연구원 서울과학수사연구소 유전자분석과 ]