Earticle

현재 위치 Home

Experiments and Numerical Simulation of Flow Field Inner the Chain Plate Fiber Dryer

첫 페이지 보기
  • 발행기관
    보안공학연구지원센터(IJCA) 바로가기
  • 간행물
    International Journal of Control and Automation SCOPUS 바로가기
  • 통권
    Vol.8 No.3 (2015.03)바로가기
  • 페이지
    pp.115-126
  • 저자
    Li Hui, Wang Rui-li
  • 언어
    영어(ENG)
  • URL
    https://www.earticle.net/Article/A241871

※ 원문제공기관과의 협약기간이 종료되어 열람이 제한될 수 있습니다.

원문정보

초록

영어
The numerical calculation model was founded on partial data of the actual test of flow field in chain plate fiber dryer, then the computational fluid dynamics (CFD) software Fluent was adopted to analyze the numerical result of dryer box unit. The result show: the numerical calculation method and data were reliable; the flow relation formula was obtained by air flow experiment in which air flew through fiber layer and chain plate, could be treated as additional momentum source term equation of air through the porous media; owing to the unreasonable setting of open porosity of air distribution plate in the dryer, there was obviously non-uniform air distribution above fiber layer, which would lead to non-uniform drying phenomenon; because of the centrifugal force of fan and diversion effect of volute, there was obvious velocity component in y direction, which could enhance the convective mass transfer effect. The research result could become the basis of design, on which the construction of chain plate fiber dryer was optimized, especially in the optimization of air distribution plate and volute of fan.

목차

Abstract
 1. Introduction
 2. The Structure of Chain Plate Dryer and Actual Test
  2.1. The Structure of Chain Plate Dryer and Operating Conditions Characteristics
  2.2. Actual Cold Test
  2.3. Resistance Test of Cotton Fiber Layer
 3. Establishment of Computational Fluid Dynamics Model
  3.1. Model Simplification and Mesh
  3.2. Turbulence Model and Boundary Conditions
 4. Comparison and Analysis of Results
  4.1. Flow Field Upper the Air Distribution Plate
  4.2. Flow Field Upper the Fiber Layer
  4.3. Overall Analysis of the Air Flow Field in the Dryer
 5. Conclusions
 6. Symbol Description
 References

키워드

Chain plate fiber dryer Numerical simulation Porous media Optimization

저자

  • Li Hui [ Huang He science and Technology University ]
  • Wang Rui-li [ Huang He science and Technology University ]

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    보안공학연구지원센터(IJCA) [Science & Engineering Research Support Center, Republic of Korea(IJCA)]
  • 설립연도
    2006
  • 분야
    공학>컴퓨터학
  • 소개
    1. 보안공학에 대한 각종 조사 및 연구 2. 보안공학에 대한 응용기술 연구 및 발표 3. 보안공학에 관한 각종 학술 발표회 및 전시회 개최 4. 보안공학 기술의 상호 협조 및 정보교환 5. 보안공학에 관한 표준화 사업 및 규격의 제정 6. 보안공학에 관한 산학연 협동의 증진 7. 국제적 학술 교류 및 기술 협력 8. 보안공학에 관한 논문지 발간 9. 기타 본 회 목적 달성에 필요한 사업

간행물

  • 간행물명
    International Journal of Control and Automation
  • 간기
    월간
  • pISSN
    2005-4297
  • 수록기간
    2008~2016
  • 십진분류
    KDC 505 DDC 605

이 권호 내 다른 논문 / International Journal of Control and Automation Vol.8 No.3

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장