Earticle

현재 위치 Home

A New Approach on Digital Blood Pressure Measurement Method for u-Healthcare Systems

첫 페이지 보기
  • 발행기관
    보안공학연구지원센터(IJBSBT) 바로가기
  • 간행물
    International Journal of Bio-Science and Bio-Technology SCOPUS 바로가기
  • 통권
    Vol.7 No.1 (2015.02)바로가기
  • 페이지
    pp.169-178
  • 저자
    Boyeon Kim, Wenhai Jin, Sung Hoon Woo, Yunseok Chang
  • 언어
    영어(ENG)
  • URL
    https://www.earticle.net/Article/A241813

※ 원문제공기관과의 협약기간이 종료되어 열람이 제한될 수 있습니다.

원문정보

초록

영어
The traditional blood pressure measurement method so called Kortokoff method has to apply strong air pressure on patient’s artery that could give severe damage on artery, and has the problem that method cannot measure the blood pressure in a series or continuously. But recent engineering technology can give new solutions that can solve the problems by using digital sensors and microcomputer. In this paper, we proposed a kind of non-Kortokoff method that can get the blood pressure from patient’s digitalized arterial pulse waveform analysis without air pressure on patient’s artery. This method can check patient’s blood pressure in a series through converting the continuous arterial pulse waveform into the absolute systolic and diastolic values with pre-defined blood pressure mapping equation from experiments. The experimental results showed that the proposed non-Kortokoff blood pressure measurement method has very good accuracy over 95% compare to commercial tonometers in continuous measurement. Also, the proposed non-Kortokoff blood pressure measurement method can be designed and implemented as a small device since it has no mechanical air pressure compartment, and applied on the u-Healthcare service areas very effectively such as a digital blood pressure checker for usual life blood pressure monitoring along with the medical device for home and hospitals.

목차

Abstract
 1. Introduction
 2. Related Works
 3. Methodology
 4. Measurement Environment
  4.1. Design of Non-Kortokoff Type Tonometer
  4.2. Experimental Environments and Procedures
 5. Experimental Results
  5.1. Blood Pressure Mapping Equation
  5.2. Type of Arterial Pulse Waveform
  5.3. Accuracy Comparison Results
 6. Conclusion
 References

키워드

Arterial pulse waveform Non-Kortokoff method Continuous blood pressure measurement u-Healthcare

저자

  • Boyeon Kim [ Division of Computer Software and Engineering, Hanyang University, Seoul, Korea ]
  • Wenhai Jin [ Department of Computer Engineering, Daejin University, Pocheon, Korea ]
  • Sung Hoon Woo [ Department of Research, uMedix Co, Sungnam, Korea ]
  • Yunseok Chang [ Department of Computer Engineering, Daejin University, Pocheon, Korea ]

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    보안공학연구지원센터(IJBSBT) [Science & Engineering Research Support Center, Republic of Korea(IJBSBT)]
  • 설립연도
    2006
  • 분야
    공학>컴퓨터학
  • 소개
    1. 보안공학에 대한 각종 조사 및 연구 2. 보안공학에 대한 응용기술 연구 및 발표 3. 보안공학에 관한 각종 학술 발표회 및 전시회 개최 4. 보안공학 기술의 상호 협조 및 정보교환 5. 보안공학에 관한 표준화 사업 및 규격의 제정 6. 보안공학에 관한 산학연 협동의 증진 7. 국제적 학술 교류 및 기술 협력 8. 보안공학에 관한 논문지 발간 9. 기타 본 회 목적 달성에 필요한 사업

간행물

  • 간행물명
    International Journal of Bio-Science and Bio-Technology
  • 간기
    격월간
  • pISSN
    2233-7849
  • 수록기간
    2009~2016
  • 등재여부
    SCOPUS
  • 십진분류
    KDC 505 DDC 605

이 권호 내 다른 논문 / International Journal of Bio-Science and Bio-Technology Vol.7 No.1

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장