Earticle

현재 위치 Home

PAPER

IMPROVEMENT OF DOSE CALCULATION ACCURACY ON kV CBCT IMAGES WITH CORRECTED ELECTRON DENSITY TO CT NUMBER CURVE

첫 페이지 보기
  • 발행기관
    대한방사선방어학회 바로가기
  • 간행물
    방사선방어학회지 KCI 등재 바로가기
  • 통권
    VOLUME 40 NUMBER 1 (2015.03)바로가기
  • 페이지
    pp.17-24
  • 저자
    Beom Seok Ahn, Hong-Gyun Wu, Sook Hyun Yoo, Jong Min Park
  • 언어
    영어(ENG)
  • URL
    https://www.earticle.net/Article/A241715

원문정보

초록

영어
To improve accuracy of dose calculation on kilovoltage cone beam computed tomography (kV CBCT) images, a custom-made phantom was fabricated to acquire an accurate CT number to electron density curve by full scatter of cone beam x-ray. To evaluate the dosimetric accuracy, 9 volumetric modulated arc therapy (VMAT) plans for head and neck (HN) cancer and 9 VMAT plans for lung cancer were generated with an anthropomorphic phantom. Both CT and CBCT images of the anthropomorphic phantom were acquired and dose-volumetric parameters on the CT images with CT density curve (CTCT), CBCT images with CT density curve (CBCTCT) and CBCT images with CBCT density curve (CBCTCBCT) were calculated for each VMAT plan. The differences between CTCT vs. CBCTCT were similar to those between CTCT vs. CBCTCBCT for HN VMAT plans. However, the differences between CTCT vs. CBCTCT were larger than those between CTCT vs. CBCTCBCT for lung VMAT plans. Especially, the differences in D98% and D95% of lung target volume were statistically significant (4.7% vs. 0.8% with p = 0.033 for D98% and 4.8% vs. 0.5% with p = 0.030 for D95%). In order to calculate dose distributions accurately on the CBCT images, CBCT density curve generated with full scatter condition should be used especially for dose calculations in the region of large inhomogeneity.

목차

Abstract
 1. INTRODUCTION
 2. MATERIALS AND METHODS
  2.1 Electron density vs. CT number
  2.2 Generation of VMAT plans
  2.3 Calculation of dose-volumetric parameters
  2.4 Data analysis
 3. RESULTS
  3.1 Mass density and electron density vs. CT numbers
  3.2 Changes in dose-volumetric parameters of headand neck VMAT plans
  3.3 Changes in dose-volumetric parameters of lung VMAT plans
 4. DISCUSSION
 5. Conclusion
 REFERENCES

키워드

Cone beam computed tomography Dose calculation Inhomogeneity correction Volumetric modulated arc therapy

저자

  • Beom Seok Ahn [ Department of Radiation Oncology, Seoul National University Hospital ]
  • Hong-Gyun Wu [ Department of Radiation Oncology, Seoul National University Hospital, Department of Radiation Oncology, Seoul National University College of Medicine ]
  • Sook Hyun Yoo [ Department of Radiation Oncology, Seoul National University Hospital ]
  • Jong Min Park [ Department of Radiation Oncology, Seoul National University Hospital ] Corresponding author

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    대한방사선방어학회 [Korean Association For Radiation Protection]
  • 설립연도
    1975
  • 분야
    자연과학>기타자연과학
  • 소개
    회원 상호간의 협조와 친목을 도모함으로써 방사선방어에 관한 제반연구 및 발전에 이바지함을 물론 학술의 국제교류 및 국제학술단체와의 상호협력 증진에 기여함을 목적으로 하며, 이 목적을 달성하기 위하여 다음 각 호의 사업을 한다. 1. 방사선방어에 관한 학술연구발표회 및 강연회 등의 개최 2. 학회지 및 방사선방어에 관한 학술간행물의 발행 및 배포 3. 방사선방어에 관한 학술의 국제교류 및 협력 4. 방사선방어에 관한 국제학술자료의 조사, 수집 및 번역 5. 방사선방어에 관한 조사 및 연구용역 6. 회원의 연구활동을 위한 제반협조 7. 기타 본 학회의 목적 달성에 필요한 사항

간행물

  • 간행물명
    방사선방어학회지 [Journal of Radiation Protection and Research]
  • 간기
    계간
  • pISSN
    2508-1888
  • 수록기간
    1976~2026
  • 등재여부
    KCI 등재,SCOPUS
  • 십진분류
    KDC 559 DDC 629

이 권호 내 다른 논문 / 방사선방어학회지 VOLUME 40 NUMBER 1

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.