The Advanced Metering Infrastructure (AMI) is an essential part of the smart water grid. One of the daunting challenges in realizing the services in the AMI system is the security issue. In this paper first we investigate the AMI communication system, and then address security requirements for water meters in the AMI system. We point out the distinguished features of the water meter compared to the smart meter. Then, we address the issues for developing the water meter in three aspects: key distribution, deployment and implementation. Finally, we propose security measures that we take in developing security modules for the smart water meter to meet these requirements.
목차
Abstract 1. Introduction 2. Communication Network 3. Security Requirements 4. Challenges 4.1 Key distribution 4.2 Deployment 4.3 Implementation 5. Security measures and development 5.1 Trust base 5.2 Key exchange and refreshment 5.3 Data authentication 5.4 Experimental network 5.5 Development of security module 6. Conclusion References
키워드
smart water meterAMIsecuritysmart water grid
저자
Sugwon Hong [ Dept. of Computer Engineering, Myongji Univ. ]
Hyung-Mo Park [ Passtech Co., Ltd. ]
Soo-Kwon Chae [ Dept. of Environmental Health and Safety, Eulji Univ. ]
Corresponding Author
1. 보안공학에 대한 각종 조사 및 연구
2. 보안공학에 대한 응용기술 연구 및 발표
3. 보안공학에 관한 각종 학술 발표회 및 전시회 개최
4. 보안공학 기술의 상호 협조 및 정보교환
5. 보안공학에 관한 표준화 사업 및 규격의 제정
6. 보안공학에 관한 산학연 협동의 증진
7. 국제적 학술 교류 및 기술 협력
8. 보안공학에 관한 논문지 발간
9. 기타 본 회 목적 달성에 필요한 사업