Earticle

현재 위치 Home

Effect of Structure Parameters and Wavelength on the Casein Concentration Detected by the Method of Scattered Transmitted Ratio

첫 페이지 보기
  • 발행기관
    보안공학연구지원센터(IJHIT) 바로가기
  • 간행물
    International Journal of Hybrid Information Technology 바로가기
  • 통권
    Vol.7 No.3 (2014.05)바로가기
  • 페이지
    pp.383-390
  • 저자
    Yong Qin, Zhen Zhou, Lijie Wang
  • 언어
    영어(ENG)
  • URL
    https://www.earticle.net/Article/A230354

※ 원문제공기관과의 협약기간이 종료되어 열람이 제한될 수 있습니다.

원문정보

초록

영어
The objectives of this study were to investigate the effect on the casein concentration detected by the method of scattered transmitted ratio (STR) at different structure parameters and wavelength. Detection experiments were performed at four kinds of testing devices and five kinds’ different wavelength lasers. All measurements had good reproducibility. Both structure parameters and wavelength had a significant effect on the measured effective concentration of the casein. The design of four different structure of the testing device was measured and analyzed. And the structure parameter of the testing device was determined in this paper. Compared measured value with standard value, it was determined by more effective wavelength. The accuracy of the method of scattered transmitted ratio, evaluated through the correlation coefficient (R) and the root mean square error of prediction (RMSEP) for five kinds different wavelength lasers. Overall, the results of this study suggest that the suitable structure parameter was experimented for testing devices.

목차

Abstract
 1. Introduction
 2. Casein composition detection system
  3.1. Structure of detection system
  3.2. Light intensity detection unit
 4. Experiment
  4.1 Experiment instrument and sample
  4.2. Evaluation of testing device
 5. Analysis the influences of concentration measurement in different wavelengths
 6. Conclusions
 ACKNOWLEDGEMENTS
 References

키워드

casein concentration structure parameters scattered transmitted ratio laser wavelength

저자

  • Yong Qin [ School of Measurement and Communication Engineering,Harbin University of Science and Technology, HeiLongJiang Harbin 150080, China, the Higher Educational Key Laboratory on Measuring & Control Technology and Instrumentations of Heilongjiang Province, HeiLongJiang Harbin 150080,China ]
  • Zhen Zhou [ School of Measurement and Communication Engineering,Harbin University of Science and Technology, HeiLongJiang Harbin 150080, China, the Higher Educational Key Laboratory on Measuring & Control Technology and Instrumentations of Heilongjiang Province, HeiLongJiang Harbin 150080,China ]
  • Lijie Wang [ School of Measurement and Communication Engineering,Harbin University of Science and Technology, HeiLongJiang Harbin 150080, China, the Higher Educational Key Laboratory on Measuring & Control Technology and Instrumentations of Heilongjiang Province, HeiLongJiang Harbin 150080,China ]

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    보안공학연구지원센터(IJHIT) [Science & Engineering Research Support Center, Republic of Korea(IJHIT)]
  • 설립연도
    2006
  • 분야
    공학>컴퓨터학
  • 소개
    1. 보안공학에 대한 각종 조사 및 연구 2. 보안공학에 대한 응용기술 연구 및 발표 3. 보안공학에 관한 각종 학술 발표회 및 전시회 개최 4. 보안공학 기술의 상호 협조 및 정보교환 5. 보안공학에 관한 표준화 사업 및 규격의 제정 6. 보안공학에 관한 산학연 협동의 증진 7. 국제적 학술 교류 및 기술 협력 8. 보안공학에 관한 논문지 발간 9. 기타 본 회 목적 달성에 필요한 사업

간행물

  • 간행물명
    International Journal of Hybrid Information Technology
  • 간기
    격월간
  • pISSN
    1738-9968
  • 수록기간
    2008~2016
  • 십진분류
    KDC 505 DDC 605

이 권호 내 다른 논문 / International Journal of Hybrid Information Technology Vol.7 No.3

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장