This paper proposes the transmission power control technique considering the shortest-path to minimize the hop-count without the occurrence of any power control messages. We applied the proposed technique on tree-based network component implemented on Tiny-OS. And we measured the transmission energy with 21 motes. Compared to before, the proposed technique consumes 75% of the transmission energy of the maximum transmission power solution. As a result of considering the shortest-path, the hop-count considering the shortest-path was about 40% less than a normal network.
목차
Abstract 1. Introduction 2. Transmission Power Control Considering the Shortest Path 2.1. Setup the reference value 2.2. Closed Loop 2.3. Determining the transmission power level 3. Implementation the System 3.1. Evaluating the performance of the system 4. Conclusion References
키워드
Sensor NetworkTransmission Power ControlTiny-OSShortest-PathHop-count