Indirect Measurement of Central Aortic Pressure using Carotid and Radial Pulses

첫 페이지 보기
  • 발행기관
    보안공학연구지원센터(IJBSBT) 바로가기
  • 간행물
    International Journal of Bio-Science and Bio-Technology SCOPUS 바로가기
  • 통권
    Vol.5 No.3 (2013.06)바로가기
  • 페이지
    pp.29-40
  • 저자
    Jae Joong Im, Ran Wei, Young Chul Lim, Chan Song Hwang, Hee Sun Kim, Moo Yong Rhee
  • 언어
    영어(ENG)
  • URL
    https://www.earticle.net/Article/A207164

※ 원문제공기관과의 협약기간이 종료되어 열람이 제한될 수 있습니다.

원문정보

초록

영어
Aortic blood pressure is more meaningful than brachial blood pressures for clinical diagnosis, and ambulatory blood pressure monitoring is better predictor for the outcomes than clinical blood pressure monitoring. However, there are few devices which provide continuous central blood pressures and arterial stiffness noninvasively. In this study, pressure sensors were developed to detect two radial and one carotid pulse waveforms. Central aortic pulse, two radial pulses and carotid pulse were recorded simultaneously during surgery. Parameters were extracted and the relationships among them were examined. Standard deviations for radial and carotid pulse pressures were all within the range of ±5 mmHg for every experimental setup. Augmentation index from aortic pulse showed much lower value than that from the radial sites, and the values of averaged augmentation index showed different trends, which might be caused by the different force applied to the pressure sensor on the carotid artery. The observed correlation, not only between the RADI SBP and estimated SBP, but also between the pulse pressure measured by the RADI pressure wire and estimated pulse pressure, proved the usefulness of the estimated central blood pressure obtained from the radial pressure pulse waveform using the ARX model.

목차

Abstract
 1. Introduction
 2. Methods
  2.1. Sensor design
  2.2. Data collection
  2.3. Data conditioning and transfer function
  2.4. Data analysis
 3. Results and discussion
 4. Conclusions
 References

키워드

Aortic pulse Blood pressure Pressure sensor Carotid pulse Radial Pulse

저자

  • Jae Joong Im [ Division of Electronic Engineering, Chonbuk National University, Jeonju, Korea ]
  • Ran Wei [ School of Electronics and Information Engineering, Tianjin Polytechnic University, Xiqing, Tianjin, China ]
  • Young Chul Lim [ Division of Electronic Engineering, Chonbuk National University, Jeonju, Korea ]
  • Chan Song Hwang [ Division of Electronic Engineering, Chonbuk National University, Jeonju, Korea ]
  • Hee Sun Kim [ UnC Co., Ltd., JeonJu, Korea ]
  • Moo Yong Rhee [ Cardiovascular Center, Dongguk University College of Medicine, Ilsan Hospital, Goyang, Korea ]

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    보안공학연구지원센터(IJBSBT) [Science & Engineering Research Support Center, Republic of Korea(IJBSBT)]
  • 설립연도
    2006
  • 분야
    공학>컴퓨터학
  • 소개
    1. 보안공학에 대한 각종 조사 및 연구 2. 보안공학에 대한 응용기술 연구 및 발표 3. 보안공학에 관한 각종 학술 발표회 및 전시회 개최 4. 보안공학 기술의 상호 협조 및 정보교환 5. 보안공학에 관한 표준화 사업 및 규격의 제정 6. 보안공학에 관한 산학연 협동의 증진 7. 국제적 학술 교류 및 기술 협력 8. 보안공학에 관한 논문지 발간 9. 기타 본 회 목적 달성에 필요한 사업

간행물

  • 간행물명
    International Journal of Bio-Science and Bio-Technology
  • 간기
    격월간
  • pISSN
    2233-7849
  • 수록기간
    2009~2016
  • 등재여부
    SCOPUS
  • 십진분류
    KDC 505 DDC 605

이 권호 내 다른 논문 / International Journal of Bio-Science and Bio-Technology Vol.5 No.3

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장