A novel method using mode component inductance parameter of shunt reactors is presented in order to identify temporary faults and permanent faults for three-phase adaptive reclosure on transmission lines with shunt reactors at both ends. The method uses π-type equivalent model as the prototype to build parameter identification formula. When some single phase-to-ground fault occurs, the parameter identification formula of zero-mode component is built; when some phase-to-phase fault occurs, the parameter identification formula of line-mode component is built. The current of the shunt reactor is given and the inductance of the shunt reactor is taken as the unknown parameter to evaluate the difference between the calculated inductance and the actual one so as to distinguish permanent fault from transient fault. The inductance difference of the temporary fault is minute because the actual fault model is consistent with the prototype. But the inductance difference of the permanent fault is distinct because the actual fault model is inconsistent with the prototype. Results of EMTP simulation show that the proposed method is reliable and effective, and can be applied to the three-phase adaptive reclosure on transmission lines with shunt reactors.

목차

Abstract
 1. Introduction
 2. Principle of Identifying Permanent Fault
 3.Formula of Parameter Identification for Transmission Lines with One-terminal Shunt Reactors
  3.1. Equivalent Model for Temporary Fault of Three-phase Transmission System
  3.2. Identification Formula based on Zero-mode Parameter
  3.3. Analysis of Temporary Fault Line Model
 4. Formula of Parameter Identification for Transmission Lines with Two-terminal Shunt Reactors
 5. Principle Analysis and Criterion
  5.1. Principle Analysis
  5.2. The Data Processing
  5.3. Criterion for Permanent Fault
 6. Simulation and Verification
  6.1 The simulation system and its parameters
  6.2. Simulation and Verification
 7. Conclusion
 Acknowledgments
 References

저자

  • Zhanjun Qiao [ Department of Mechanical and Electronic Engineering, North China Institute of Science and Technology, East Yanjiao, Beijing, China ]
  • Wenbo Fan [ China Coal Construction Group Co,Ltd, Changping, Beijing, China ]

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    보안공학연구지원센터(IJSH) [Science & Engineering Research Support Center, Republic of Korea(IJSH)]
  • 설립연도
    2006
  • 분야
    공학>컴퓨터학
  • 소개
    1. 보안공학에 대한 각종 조사 및 연구 2. 보안공학에 대한 응용기술 연구 및 발표 3. 보안공학에 관한 각종 학술 발표회 및 전시회 개최 4. 보안공학 기술의 상호 협조 및 정보교환 5. 보안공학에 관한 표준화 사업 및 규격의 제정 6. 보안공학에 관한 산학연 협동의 증진 7. 국제적 학술 교류 및 기술 협력 8. 보안공학에 관한 논문지 발간 9. 기타 본 회 목적 달성에 필요한 사업

간행물

  • 간행물명
    International Journal of Smart Home
  • 간기
    격월간
  • pISSN
    1975-4094
  • 수록기간
    2008~2016
  • 십진분류
    KDC 505 DDC 605

이 권호 내 다른 논문 / International Journal of Smart Home Vol.7 No.5

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장