Earticle

현재 위치 Home

A study on Improvement for distorted images of the Digital X-ray Scanner System based on Fuzzy Correction Algorithm

첫 페이지 보기
  • 발행기관
    한국정보기술응용학회 바로가기
  • 간행물
    한국정보기술응용학회 학술대회 바로가기
  • 통권
    2005년도 6th 2005 International Conference on Computers, Communications and System (2005.11)바로가기
  • 페이지
    pp.173-176
  • 저자
    Baek, Jae-Ho, Kim, Kyung-Jung, Park, Mi-Gnon
  • 언어
    영어(ENG)
  • URL
    https://www.earticle.net/Article/A166182

※ 기관로그인 시 무료 이용이 가능합니다.
※ 학술발표대회집, 워크숍 자료집 중 4페이지 이내 논문은 '요약'만 제공되는 경우가 있으니, 구매 전에 간행물명, 페이지 수 확인 부탁 드립니다.

4,000원

원문정보

초록

영어
This paper proposes a fuzzy correction algorithm that can correct the distorted medical image caused by the scanning nonlinear velocity of the Digital X-ray Scanner System (DX-Scanner) using the Multichannel Ionization Chamber (MIC). In the DX-Scanner, the scanned medical image is distorted for reasons of unsuitable integration time at the nonlinear acceleration period of the AC servo motor during the inspection of patients. The proposed algorithm finds the nonlinear motor velocity modeling through fuzzy system by clustering and reconstructs the normal medical image lines by calculating the suitable moving distance with the velocity of the motor using the modeling, acceleration time and integration time. In addition, several image processing is included in the algorithm. This algorithm analyzes exact pixel lines by comparing the distance of the acceleration period with the distance of the uniform velocity period in every integration time and is able to compensate for the velocity of the acceleration period. By applying the proposed algorithm to the test pattern for checking the image resolution, the effectiveness of this algorithm is verified. The corrected image obtained from distorted image is similar to the normal and better image for a doctor's diagnosis.

목차

Ahstract
 1 Introduction
 2 Fuzzy Systems
 3 Digital X-ray Scanner System
 4 Velocity Specification of AC Servo Motor and Distorted Image
 5 Fuzzy Correction AIgorithm
 6 Experimental Results
 7 Conclusions
 References

키워드

digital X-ray radiography; distorted image; fuzzy algorithm; image correction

저자

  • Baek, Jae-Ho [ Department of Electrical and Electronic Engineering Yonsei University ]
  • Kim, Kyung-Jung [ Department of Electrical and Electronic Engineering Yonsei University ]
  • Park, Mi-Gnon [ Department of Electrical and Electronic Engineering Yonsei University ]

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    한국정보기술응용학회 [The Korea Society of Information Technology Applications]
  • 설립연도
    1999
  • 분야
    사회과학>경영학
  • 소개
    본 학회는 정보기술 관련 분야의 연구 및 교류를 촉진하여 국가 및 기업정보화 발전에 공헌함을 그 목적으로 한다.

간행물

  • 간행물명
    한국정보기술응용학회 학술대회
  • 간기
    부정기
  • 수록기간
    2001~2011
  • 십진분류
    KDC 005 DDC 005

이 권호 내 다른 논문 / 한국정보기술응용학회 학술대회 2005년도 6th 2005 International Conference on Computers, Communications and System

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장