THREE‐DIMENSIONAL VERIFICATION OF INTRACRANIAL TARGET POINT DEVIATION USING MRI‐BASED POLYMER‐GEL DOSIMETRY FOR CONVENTIONAL AND FRACTIONATED STEREOTACTIC RADIOSURGERY
Conventional (SRS) and fractionated (FSRS) stereotactic radiosurgery necessarily require stringent overall target point accuracy and precision. We determine three‐dimensional intracranial target point deviations (TPDs) in a whole treatment procedure using magnetic resonance image (MRI)‐based polymer‐gel dosimetry, and suggest a technique for overall system tests. TPDs were measured using a custom‐made head phantom and gel dosimetry. We calculated TPDs using a treatment planning system. Then, we compared TPDs using mid bi‐plane and three‐dimensional volume methods with spherical and elliptical targets to determine their inherent analysis errors; finally, we analyzed regional TPDs using the latter method. Average and maximum additive errors for ellipses were 0.62 and 0.69 mm, respectively. Total displacements were 0.92 ± 0.25 and 0.77 ± 0.15 mm for virtual SRS and FSRS, respectively. Average TPDtotal at peripheral regions was greater than that at central regions for both. Overall system accuracy was similar to that reported previously. Our technique could be used as an overall system accuracy test that considers the real radiation field shape.
목차
Abstract 1. INTRODUCTION 2. METHODS AND MATERIALS 2.1. Experimental 2.2. Head phantom 2.3. Gel preparation 2.4. Treatment planning and irradiation 2.5. MRI scan and gel calibration 2.6. MR signal attenuation and threshold 2.7. Comparison of analysis methods 2.8. TPD evaluation 3. RESULTS AND DISCUSSION 3.1. Comparison of analysis methods 3.2. TPD evaluation in various brain regions 3.3. Comprehensive summary and meaning of the TPD results 4. CONCLUSIONS REFERENCES
키워드
RadiosurgeryOverall system testTarget point deviationPolymer gelMRI
저자
Kyung-Nam Lee [ Department of Biomedical Engineering, College of Medicine, The Catholic University of Korea, ]
Dong-Joon Lee [ Research Institute of Biomedical Engineering, College of Medicine, The Catholic University of Korea ]
Corresponding author
Tae-Suk Suh [ Department of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Department of Neurosurgery, Ilsanpaik Hospital, College of Medicine, Inje University ]
대한방사선방어학회 [Korean Association For Radiation Protection]
설립연도
1975
분야
자연과학>기타자연과학
소개
회원 상호간의 협조와 친목을 도모함으로써 방사선방어에 관한 제반연구 및 발전에 이바지함을 물론 학술의 국제교류 및 국제학술단체와의 상호협력 증진에 기여함을 목적으로 하며, 이 목적을 달성하기 위하여 다음 각 호의 사업을 한다.
1. 방사선방어에 관한 학술연구발표회 및 강연회 등의 개최
2. 학회지 및 방사선방어에 관한 학술간행물의 발행 및 배포
3. 방사선방어에 관한 학술의 국제교류 및 협력
4. 방사선방어에 관한 국제학술자료의 조사, 수집 및 번역
5. 방사선방어에 관한 조사 및 연구용역
6. 회원의 연구활동을 위한 제반협조
7. 기타 본 학회의 목적 달성에 필요한 사항
간행물
간행물명
방사선방어학회지 [Journal of Radiation Protection and Research]