Comparison of modified airlift reactor with conventional airlift reactor

첫 페이지 보기
  • 발행기관
    보안공학연구지원센터(IJCA) 바로가기
  • 간행물
    International Journal of Control and Automation SCOPUS 바로가기
  • 통권
    vol.3 no.3 (2010.09)바로가기
  • 페이지
    pp.25-40
  • 저자
    T.K. Ghosh, Shounak Banerjee, C.B. Majumder, Tai-hoon Kim
  • 언어
    영어(ENG)
  • URL
    https://www.earticle.net/Article/A147517

※ 원문제공기관과의 협약기간이 종료되어 열람이 제한될 수 있습니다.

원문정보

초록

영어
Air supply is a crucial parameter for many aerobic processes. Specific growth rate (μ) was determined for both the reactors (conventional UT-ALF and modified CDT-ALF) under identical operating conditions. The conventional uniform tube external loop airlift fermenter (UT-ALF) was modified keeping the volume and height same. Only the riser part of the conventional external loop airlift fermenter was replaced by a irregular geometry in the form of converging-diverging tube. The modified system is thus named converging-diverging tube airlift fermenter (CDT-ALF), which possesses a novel geometry comprised of walls with sinusoidal waves that mimic baffles in an effort to promote mixing at low Reynold’s number (Re). This geometry provides a unique hydrodynamic environment suitable also for the cultivation of mammalian cells and tissues.
The results from UT-ALF and CDT-ALF were compared. At any operating condition CDTALF showed higher μmax (maximum specific growth rate) compared to UT-ALF. The highest (μmax) was observed for CDT-ALF corresponding to an initial sugar concentration of 50 kg/m3 and air flow rate of 1.0 vvm. This was 29 % higher compared to UT-ALF under identical operating conditions. So, operating cost may be minimized to a great extent if commercialized.

목차

Abstract
 1. Introduction
 2. Experimental
 3. Materials and methods
 4. Results and Discussion
  4.1 Dependence of specific growth rate ( μ) on air flow rate and initial glucoseconcentration of 10 kg/m3 and 30 kg/m3
  4.2 Effect of air flow rate on specific growth rate (μ) when initial glucoseconcentration was increased to 50 kg/m3
 5. Discussion
  5.1 Effect of air flow rate on μ max at sugar conc. 50 kg/m3 and above.
 6. Conclusion
 7. Acknowledgement
 8. References

키워드

Airlift bioreactor Aeration Aerobic process Animal cell Culture Specific growth rate.

저자

  • T.K. Ghosh [ Department of Biotechnology, Heritage Institute of Technology ]
  • Shounak Banerjee [ Department of Biotechnology, Heritage Institute of Technology ]
  • C.B. Majumder [ Department of Chemical Engineering Indian Institute of Technology ]
  • Tai-hoon Kim [ Hannam University ] Corresponding Author

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    보안공학연구지원센터(IJCA) [Science & Engineering Research Support Center, Republic of Korea(IJCA)]
  • 설립연도
    2006
  • 분야
    공학>컴퓨터학
  • 소개
    1. 보안공학에 대한 각종 조사 및 연구 2. 보안공학에 대한 응용기술 연구 및 발표 3. 보안공학에 관한 각종 학술 발표회 및 전시회 개최 4. 보안공학 기술의 상호 협조 및 정보교환 5. 보안공학에 관한 표준화 사업 및 규격의 제정 6. 보안공학에 관한 산학연 협동의 증진 7. 국제적 학술 교류 및 기술 협력 8. 보안공학에 관한 논문지 발간 9. 기타 본 회 목적 달성에 필요한 사업

간행물

  • 간행물명
    International Journal of Control and Automation
  • 간기
    월간
  • pISSN
    2005-4297
  • 수록기간
    2008~2016
  • 십진분류
    KDC 505 DDC 605

이 권호 내 다른 논문 / International Journal of Control and Automation vol.3 no.3

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장