Earticle

현재 위치 Home

바이오센서 및 바이오칩

Self-assembly Lipid Bilayer Membrane Using PDMS Gasket

첫 페이지 보기
  • 발행기관
    한국생물공학회 바로가기
  • 간행물
    한국생물공학회 학술대회 바로가기
  • 통권
    2010 추계학술대회 및 국제심포지움 (2010.10)바로가기
  • 페이지
    pp.253-253
  • 저자
    You-Hyo BAEK, JoonJin PARK, Tae-Joon JEON
  • 언어
    영어(ENG)
  • URL
    https://www.earticle.net/Article/A129624

※ 원문제공기관과의 협약기간이 종료되어 열람이 제한될 수 있습니다.

원문정보

초록

영어
Planar bilayer lipid membranes (BLMs) are primary tools in studying ion channels that working lipid bilayer and bio screening. Painting methods, introduced by Muller, are used widely but the method has several drawbacks of needed high skilled operator and lack of stability that assemble it inefficient. For this reason Mueller method has critical drawbacks as substituted by patch clamp method, another gold standard method to study ion channels in live cell. Consequently, Mueller method to assemble lipid bilayer has been studied for increasing stability, lessen intensive labor and decreasing degree of skill required. First, we use high melting point lipid solution which 2:8 squalene and hexadecane mixture. The lipid solution freezes at ~14°C. The lipid solution was deposited a small aperture and frozen before using at experiment. The membrane precursor can be stored freezing and enabling transportation. This membrane precursor can be transported to other place and thawed where a membrane is needed. However, using high melting point lipid solution method has a low success rate (~30%) and various thinning out time. To overcome the problem, pin tool is used for exact volume control in previous work. Despite increased precision of deposition, several problems remained. To resolve problems we used PDMS gasket instead of conventional hydrophobic films.
PDMS gasket extracts organic solvent, promoting lipid bilayer formation. This characteristic advanced optimization and at the same time reduced the membrane formation time to ~30 minutes.
Membranes were created timely in a controlled. Adapt to automated array system. An array of lipid bilayer membrane can be developed for the potential use of high-throughput ion channel screening.
To exhibit high-throughput measurement of ion channels use an analog switch, enabling sequential measurement of each membrane using just one amplifier. Membranes measured using this switch were shown identical to those in the conventional system. We will show a number of potential applications using our membrane system. BLMs can be used for high-throughput screening.

키워드

Self-assembly Lipid Bilayer Membrane Using PDMS Gasket

저자

  • You-Hyo BAEK [ Department of Biological Engineering, Inha University, 402-751. ]
  • JoonJin PARK [ Department of Biological Engineering, Inha University, 402-751. ]
  • Tae-Joon JEON [ Department of Biological Engineering, Inha University, 402-751. ]

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    한국생물공학회 [The Korean Society for Biotechnology and Bioengineering]
  • 설립연도
    1984
  • 분야
    공학>생물공학
  • 소개
    이 법인은 생물 공학의 발전과 보급에 이바지하고, 회원 상호 간의 연구 협력과 친목을 도모함을 목적으로 한다 1. 생물공학 분야의 발전을 위한 연구 협력 2. 생물공학의 실용화를 촉진시키기 위한 산학 협동 3. 학술연구 발표회, 강연회, 연수회 등 학술활동의 개최 4. 국,영문 학술지,소식지,학술회의 Proceedings 및 학술도서의 발간 5. 생물공학 발전을 위한 정책 건의 6. 기타 국제 교류 등 본 학회의 목적 달성을 위한 제반 활동

간행물

  • 간행물명
    한국생물공학회 학술대회
  • 간기
    반년간
  • 수록기간
    1985~2013
  • 십진분류
    KDC 476 DDC 576

이 권호 내 다른 논문 / 한국생물공학회 학술대회 2010 추계학술대회 및 국제심포지움

    피인용수 : 0(자료제공 : 네이버학술정보)