Earticle

현재 위치 Home

일반특강 및 신진연구자 심포지엄 : 좌장 : 윤형돈(영남대)

Fabrication of horseradish peroxidase neutral red ceramic composite biosensor and its application towards Hydrogen peroxide sensing

첫 페이지 보기
  • 발행기관
    한국생물공학회 바로가기
  • 간행물
    한국생물공학회 학술대회 바로가기
  • 통권
    2010 추계학술대회 및 국제심포지움 (2010.10)바로가기
  • 페이지
    pp.129-129
  • 저자
    Thenmozhi KATHAVARAYAN, Young Je YOO, Sriman Narayanan SANGILIMUTHU
  • 언어
    영어(ENG)
  • URL
    https://www.earticle.net/Article/A129201

※ 원문제공기관과의 협약기간이 종료되어 열람이 제한될 수 있습니다.

원문정보

초록

영어
In the last few years, considerable attention has been devoted to the immobilization of biomolecules, especially enzymes on electrode surface in relation to the development of biosensors and biotechnological processes. In this work, we immobilized HRP onto the bifunctional silane 3‐aminopropyltrimethoxy silane (APTMOS) through glutaraldehyde crosslinker. Separately, the organic mediator Neutral red was covalently crosslinked to 3‐aminopropyltrimethoxy silane using glutaraldehyde. The primary amino groups on the mediators, enzyme and the sol‐gel precursor were of advantage in the motive for covalent immobilization. Methyl trimethoxy silane was used as an additional sol‐gel monomer to maintain the hydrophilic/hydrophobic nature of the composite. The composite electrode was prepared using the above two silane mixtures along with graphite powder. The electrochemical behavior of the modified electrode was probed in using cyclic voltammetry. The biosensing application of the modified electrode was verified using hydrogen peroxide as the substrate. The biosensor showed a good linear response towards hydrogen peroxide in the range of 2.14 x 10‐7 M to 1.93 x 10‐4 M with a detection limit of 1.28 x 10‐7 M.
Kinetic parameters such as electron transfer rate constant, ks was evaluated to be 0.30 ± 0.03 s‐1 and the diffusion coefficient, α was found to be 0.27 by applying the Laviron’s method [1]. The chronoamperometric studies showed that the biosensor could sense effectively in dynamic mode. The performance of the biosensor was optimized with respect the scan rate, pH and temperature.

저자

  • Thenmozhi KATHAVARAYAN [ School of Chemical and Biological Engineering, Seoul National University, Seoul 151-741, Korea. ]
  • Young Je YOO [ School of Chemical and Biological Engineering, Seoul National University, Seoul 151-741, Korea. ]
  • Sriman Narayanan SANGILIMUTHU [ Department of Analytical Chemistry, University of Madras, Guindy Campus, Chennai 600025, India. ]

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    한국생물공학회 [The Korean Society for Biotechnology and Bioengineering]
  • 설립연도
    1984
  • 분야
    공학>생물공학
  • 소개
    이 법인은 생물 공학의 발전과 보급에 이바지하고, 회원 상호 간의 연구 협력과 친목을 도모함을 목적으로 한다 1. 생물공학 분야의 발전을 위한 연구 협력 2. 생물공학의 실용화를 촉진시키기 위한 산학 협동 3. 학술연구 발표회, 강연회, 연수회 등 학술활동의 개최 4. 국,영문 학술지,소식지,학술회의 Proceedings 및 학술도서의 발간 5. 생물공학 발전을 위한 정책 건의 6. 기타 국제 교류 등 본 학회의 목적 달성을 위한 제반 활동

간행물

  • 간행물명
    한국생물공학회 학술대회
  • 간기
    반년간
  • 수록기간
    1985~2013
  • 십진분류
    KDC 476 DDC 576

이 권호 내 다른 논문 / 한국생물공학회 학술대회 2010 추계학술대회 및 국제심포지움

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장