초록

영어
PAT is defined as a “system for the continuous analysis and control of manufacturing processes based on real‐time or rapid measurements during processing of quality and performance attributes of raw and in‐process materials and processes, to assure end product quality at the completion of the process”.
Optimal manufacturing process control involves testing raw materials, in‐process monitoring and endproduct testing with stringent documentation. Critical sources of variability must be identified and managed. PAT implementation, therefore, requires innovative PAT tools or Process Analytical Instrumentation (PAI) which gives real‐time or near real‐time results by monitoring continuous and episodic operations. In order to specifically implement PAT in testing for Bacterial Endotoxins, the Portable Testing System (Endosafe®‐PTS™) offered by Charles River is an effective Process Analytical Instrument. The PTS™ uses disposable LAL cartridges approved by the USFDA (July 2006) and are pre‐loaded with existing FDA‐approved Endosafe® Chromogenic LAL reagents. The cartridges are calibrated directly to the primary standard (Reference Standard Endotoxin EC‐6). The PTS cartridges are compliant to the current harmonized compendia test for Bacterial Endotoxins. The suitability of the PTS™ Reader comes from its highly flexible platform and portability. It gives a rapid test result time of less than 15 minutes. It eliminates the need for endotoxin standards, preparation of Positive Product Controls (PPC) and validation of accessories‐ all of which need a laboratory clean room setting and extensive analyst training. The PTS™ Reader allows the test to be done near the point‐of‐use and the cartridges can be stored at ambient temperatures for 18 months. The PTS™ allows for single sample analysis, near real time results, and decentralization from QC labs – all of which ultimately contribute to manufacturing process control and a quick response to contamination issues. By implementing PAT and the PTS™ rapid endotoxin testing system, this turnaround time for sample release would be reduced to just 30 minutes allowing manufacturing to move forward without delay.
Using the PTS™/MCS™ systems as Process Analytical instruments can reduce risks in the manufacturing process and improve results in the quality of end‐products.

저자

  • Hongjin MIN [ Charles River Laboratories Korea, Korea. ]

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    한국생물공학회 [The Korean Society for Biotechnology and Bioengineering]
  • 설립연도
    1984
  • 분야
    공학>생물공학
  • 소개
    이 법인은 생물 공학의 발전과 보급에 이바지하고, 회원 상호 간의 연구 협력과 친목을 도모함을 목적으로 한다 1. 생물공학 분야의 발전을 위한 연구 협력 2. 생물공학의 실용화를 촉진시키기 위한 산학 협동 3. 학술연구 발표회, 강연회, 연수회 등 학술활동의 개최 4. 국,영문 학술지,소식지,학술회의 Proceedings 및 학술도서의 발간 5. 생물공학 발전을 위한 정책 건의 6. 기타 국제 교류 등 본 학회의 목적 달성을 위한 제반 활동

간행물

  • 간행물명
    한국생물공학회 학술대회
  • 간기
    반년간
  • 수록기간
    1985~2013
  • 십진분류
    KDC 476 DDC 576

이 권호 내 다른 논문 / 한국생물공학회 학술대회 2010 추계학술대회 및 국제심포지움

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장