Earticle

현재 위치 Home

PAPER

ANALYSIS OF THE LiF:Mg,Cu,Si TL AND THE LiF:Mg,Cu,P TL GLOW CURVES BY USING GENERAL APPROXIMATION PLUS MODEL

첫 페이지 보기
  • 발행기관
    대한방사선방어학회 바로가기
  • 간행물
    방사선방어학회지 KCI 등재후보 바로가기
  • 통권
    VOLUME 34 NUMBER 4 (2009.12)바로가기
  • 페이지
    pp.155-164
  • 저자
    IN‐SU CHANG, JUNG‐IL LEE, JANG‐LYUL KIM, MI‐AE OH, KI‐SOO CHUNG
  • 언어
    영어(ENG)
  • URL
    https://www.earticle.net/Article/A114708

원문정보

초록

영어
In this paper, we used computerized glow curve deconvolution (CGCD) software with several models for the simulation of a TL glow curve which was used for analysis. By using the general approximation plus model, parameters values of the glow curve were analyzed and compared with the other models parameters (general approximation, mixed order kinetics, general order kinetics). The LiF:Mg,Cu,Si and the LiF:Mg,Cu,P material were used for the glow curve analysis. And we based on figure of merits (FOM) which was the goodness of the fitting that was monitored through the value between analysis model and TLD materials. The ideal value of FOM is 0 which represents a perfect fit. The main glow peak makes the most effect of radiation dose assessment of TLD materials. The main peak of the LiF:Mg,Cu,Si materials has a intensity rate 80.76% of the whole TL glow intensity, and that of LiF:Mg,Cu,P materials has a intensity rate 68.07% of the whole TL glow intensity. The activation energy of LiF:Mg,Cu,Si was analyzed as 2.39 eV by result of the general approximation plus(GAP) model. In the case of mixed order kinetics (MOK), the activation energy was analyzed as 2.29 eV. The activation energy was analyzed as 2.38 eV by the general order kinetics (GOK) model. In the case of LiF:Mg,Cu,P TLD, the activation energy was analyzed as 2.39 eV by result of the GAP model. In the case of MOK, the activation energy was analyzed as 2.55 eV. The activation energy was analyzed as 2.51 eV by the GOK model. The R value means different ratio of retrapping‐recombination. The R value of LiF:Mg,Cu,Si TLD main peak analyzed as 1.12 x 10‐6 and α value analyzed as 1.0 x 10‐3. The R of LiF:Mg,Cu,P TLD analyzed as 7.91 x 10‐4, the α value means different ratio of initial thermally trapped electron density‐initial trapped electron density (include thermally disconnected trap electrons density). The α value was analyzed as 9.17 x 10‐1 which was the difference from LiF:Mg,Cu,Si TLD. The deep trap electron density of LiF:Mg,Cu,Si was higher than the deep trap electron density of LiF:Mg,Cu,P.

목차

Abstract
 1. INTRODUCTION1)
 2. THEORY
  2.1 Thermoluminescence
  2.2 Figure of Merits (FOM
  2.3 Analysis Ability of the Glow Curve Analysis Models
 3. MATERIALS AND METHODS
  3.1 TLD Materials
  3.2 Measurement of Glow Curve
 4. RESULTS AND DISCUSSION
  4.1 Analyzed Glow Curve
  4.2 Analyzed Parameters
 5. CONCLUSION
 REFERENCES

저자

  • IN‐SU CHANG [ Korea Atomic Energy Research Institute ]
  • JUNG‐IL LEE [ Korea Atomic Energy Research Institute ]
  • JANG‐LYUL KIM [ Korea Atomic Energy Research Institute ]
  • MI‐AE OH [ Gyeongsang National University ]
  • KI‐SOO CHUNG [ Gyeongsang National University ]

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    대한방사선방어학회 [Korean Association For Radiation Protection]
  • 설립연도
    1975
  • 분야
    자연과학>기타자연과학
  • 소개
    회원 상호간의 협조와 친목을 도모함으로써 방사선방어에 관한 제반연구 및 발전에 이바지함을 물론 학술의 국제교류 및 국제학술단체와의 상호협력 증진에 기여함을 목적으로 하며, 이 목적을 달성하기 위하여 다음 각 호의 사업을 한다. 1. 방사선방어에 관한 학술연구발표회 및 강연회 등의 개최 2. 학회지 및 방사선방어에 관한 학술간행물의 발행 및 배포 3. 방사선방어에 관한 학술의 국제교류 및 협력 4. 방사선방어에 관한 국제학술자료의 조사, 수집 및 번역 5. 방사선방어에 관한 조사 및 연구용역 6. 회원의 연구활동을 위한 제반협조 7. 기타 본 학회의 목적 달성에 필요한 사항

간행물

  • 간행물명
    방사선방어학회지 [Journal of Radiation Protection and Research]
  • 간기
    계간
  • pISSN
    2508-1888
  • 수록기간
    1976~2026
  • 등재여부
    KCI 등재,SCOPUS
  • 십진분류
    KDC 559 DDC 629

이 권호 내 다른 논문 / 방사선방어학회지 VOLUME 34 NUMBER 4

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장