Kwan Sik Chun, Sung Hyun Yoo, Young June Cho, Jang Pyo Hong, Wook Jin Han, Beong Soon Choi, Pil Sang Kang, Suk Ju Cho
언어
한국어(KOR)
URL
https://www.earticle.net/Article/A112345
※ 원문제공기관과의 협약기간이 종료되어 열람이 제한될 수 있습니다.
원문정보
초록
영어
To evaluate the efficiency of the decontamination plant for the removal of uranium compounds deposited on the internal surface of UF6 cylinder for its reuse, two demonstration tests of the plant with different ratio of Na2CO3 and H2O2 were carried out, and each test had 5 steps. The main chemical form removed by the tests was to be identified as Na4UO2(CO3)3. More than 50% of uranium was removed by water of the first step, and at the following steps the removal amounts were exponentially decreased. On the other hand, the result shows that the injected amount of Na2CO3 , compared with that of the removed uranium, was stoichiometrically excessed. This suggests that the injected amounts of Na2CO3 , the generation rate of decontaminated waste, and the decontamination steps could be reduced by a process optimization of the plant.
한국어
핵연료 운반용 실린더의 재사용을 위한 용기세척공장의 제염공정에 대한 성능을 평가하기 위하여 Na2CO3 + H2O2 혼합용액의 조합을 약간 달리한 2회의 시험을 실행하였다. 각 시험은 모두 일련의 5 단계에 걸쳐 실시되었다. 우라늄 제염의 주 화학종은 Na4UO2(CO3)3 로 식별되었다. 그리고 첫 단계에서의 세척액은 물이었으며, 이 단계에서 50% 이상의 우라늄이 제염되었다. 그 이후로는 단계가 더해 갈수록 우라늄의 제염양은 지수함수적으로 감소하는 경향을 나타내었으며, 화학양론적으로 제거된 우라늄에 비하여 투여된 Na2CO3 의 양은 과다함을 나타내었다. 이러한 결과들에 의하면, 공정최적화를 통하여 Na2CO3 의 투여량 감축, 세척폐액의 감량, 제염단계 축소 등을 꾀할 수 있을 것으로 판단된다.
목차
Abstract 요약 I. 서론 II. 실험 III. 결과 및 토의 가. 일차시험 나. 이차시험 VI. 결론 참고문헌
한국방사성폐기물학회는 국내 방사성폐기물 관리 분야 산ㆍ학ㆍ연 관계자들의 학술단체로 학술연구발표회 및 강연회 개최, 학술간행물 발간 등의 학술 진흥사업, 방사성폐기물에 관한 국제교류 및 협력 증진사업, 방사성폐기물에 관한 위탁연구 자문 및 평가사업 수행 등으로 국내 방사성폐기물 관리 분야 전반의 내부 역량 강화와 경쟁력 확보를 도모하고자 한다. 더 나아가 국가사회 발전에 미치는 중요성을 인식하는 계기를 만들고자 한다. 또한 이러한 활동을 통하여 국가경제 발전과 국민건강에 일조할 수 있도록 하며, 궁극적으로는 한국방사성폐기물학회가 세계 속의 학술단체로의 발전해 나가는 것을 목표로 한다.
간행물
간행물명
방사성폐기물학회지 [Journal of Nuclear Fuel Cycle and Waste Technology (JNFCWT)]