Earticle

현재 위치 Home

논문

THE EFFECT OF SURFACE ROUGHNESS OF CSI(TL) MICRO-COLUMNS ON THE RESOLUTION OF THE X-RAY IMAGE; OPTICAL SIMULATION STUDY

첫 페이지 보기
  • 발행기관
    대한방사선방어학회 바로가기
  • 간행물
    방사선방어학회지 KCI 등재후보 바로가기
  • 통권
    VOLUME 34 NUMBER 1 (2009.03)바로가기
  • 페이지
    pp.25-30
  • 저자
    HYUNKI KIM, JUN HYUNG BAE, BO KYUNG CHA, HOSANG JEON, JONG YUL KIM, CHAN KYU KIM, GYUSEONG CHO
  • 언어
    영어(ENG)
  • URL
    https://www.earticle.net/Article/A104407

원문정보

초록

영어
Micro-columnar CsI(Tl) is the most popular scintillator material which is used for many indirect digital X-ray imaging detectors. The light scattering at the surface of micro-columnar CsI(Tl) scintillator was studied to find the correlation between the surface roughness and the resultant image resolution of indirect X-ray imaging detectors. Using a commercially available optical simulation program, Light Tools, MTF (Modulation Transfer Function) curves of the CsI(Tl) film thermally evaporated on glass substrate with different thickness were calculated and compared with the experimental estimation of MTF values by the edge X-ray image method and CCD camera. It was found that the standard deviation value of Gaussian scattering model which is determined by the surface roughness of micro-columns could certainly change the MTF value
of image sensors. This model and calculation methodology will be beneficial to estimate the overall performance of indirect X-ray imaging system with CsI(Tl) scintillator film for optimum design depending on its application.

목차

1. INTRODUCTION
 2. SIMULATION METHOD
  2.1 Scintillation Light Distribution
  2.2 Surface Properties
  2.3 Bulk Properties
  2.4 Verification and Evaluation of Surface Roughness
 3. RESULTS AND DISCUSSION
 4. CONCLUSION
 ACKNOWLEDGEMENTS
 REFERENCES

저자

  • HYUNKI KIM [ Radiation Detection and Medical Imaging Lab, Dept. of Nucl. and Quant. Engineering, KAIST ]
  • JUN HYUNG BAE [ Radiation Detection and Medical Imaging Lab, Dept. of Nucl. and Quant. Engineering, KAIST ]
  • BO KYUNG CHA [ Radiation Detection and Medical Imaging Lab, Dept. of Nucl. and Quant. Engineering, KAIST ]
  • HOSANG JEON [ Radiation Detection and Medical Imaging Lab, Dept. of Nucl. and Quant. Engineering, KAIST ]
  • JONG YUL KIM [ Radiation Detection and Medical Imaging Lab, Dept. of Nucl. and Quant. Engineering, KAIST ]
  • CHAN KYU KIM [ Radiation Detection and Medical Imaging Lab, Dept. of Nucl. and Quant. Engineering, KAIST ]
  • GYUSEONG CHO [ Radiation Detection and Medical Imaging Lab, Dept. of Nucl. and Quant. Engineering, KAIST ] Corresponding author

참고문헌

자료제공 : 네이버학술정보

간행물 정보

발행기관

  • 발행기관명
    대한방사선방어학회 [Korean Association For Radiation Protection]
  • 설립연도
    1975
  • 분야
    자연과학>기타자연과학
  • 소개
    회원 상호간의 협조와 친목을 도모함으로써 방사선방어에 관한 제반연구 및 발전에 이바지함을 물론 학술의 국제교류 및 국제학술단체와의 상호협력 증진에 기여함을 목적으로 하며, 이 목적을 달성하기 위하여 다음 각 호의 사업을 한다. 1. 방사선방어에 관한 학술연구발표회 및 강연회 등의 개최 2. 학회지 및 방사선방어에 관한 학술간행물의 발행 및 배포 3. 방사선방어에 관한 학술의 국제교류 및 협력 4. 방사선방어에 관한 국제학술자료의 조사, 수집 및 번역 5. 방사선방어에 관한 조사 및 연구용역 6. 회원의 연구활동을 위한 제반협조 7. 기타 본 학회의 목적 달성에 필요한 사항

간행물

  • 간행물명
    방사선방어학회지 [Journal of Radiation Protection and Research]
  • 간기
    계간
  • pISSN
    2508-1888
  • 수록기간
    1976~2026
  • 등재여부
    KCI 등재,SCOPUS
  • 십진분류
    KDC 559 DDC 629

이 권호 내 다른 논문 / 방사선방어학회지 VOLUME 34 NUMBER 1

    피인용수 : 0(자료제공 : 네이버학술정보)

    함께 이용한 논문 이 논문을 다운로드한 분들이 이용한 다른 논문입니다.

      페이지 저장