Earticle

다운로드

FEM해석에 의한 단면수복재용 PCM의 염화물이온 확산 예측
Prediction on the Chloride Ion Diffusion of PCM after Patching Repair by FEM analysis

  • 간행물
    대한건축학회지회연합회 학술발표대회논문집 바로가기
  • 권호(발행년)
    2007년도 추계학술발표대회 (2007.12) 바로가기
  • 페이지
    pp.650-653
  • 저자
    박재홍, 김세영, 전봉민, 오상균
  • 언어
    한국어(KOR)
  • URL
    https://www.earticle.net/Article/A89478

원문정보

초록

영어
The chloride ion migration coefficient of polymer modified cement mortar (PCM) used as patching repair materials to the deteriorated RC structure was tested by NT BUILD 492 method. To evaluate performance of repaired section against incoming Chloride Ion, 2D-numerical analysis model (FEM) was developed. The diffusion coefficient of chloride ion decreased in proportion to the polymer cement ratio. It became clear through the analysis of FEM model that the performance change over time after repair depend on the removal range of retrograded concrete and the time of repair application.

목차

Abstract
 1. 서론
 2. PCM의 염화물이온 이동 저항성 평가
 3. 유한요소법을 이용한 수명예측
  3.1 초기조건 및 경계조건
  3.2 메쉬분할
  3.3 해석 결과
  3.4 PCM을 이용한 단면 수복 후의 염화물이온 확산
 4. 결론
 참고문헌

저자

  • 박재홍 [ Park, Jae-Hong | 동의대 대학원, 석사과정 ]
  • 김세영 [ Kim. Sea-Young | 동의대 대학원, 박사과정 ]
  • 전봉민 [ Jeon, Bong-Min | 동의대 대학원, 박사과정 ]
  • 오상균 [ Oh, Sang-Gyun | 동의대 건축공학과, 부교수, 공학박사 ]

참고문헌

자료제공 : 네이버학술정보

    간행물 정보

    • 간행물
      대한건축학회지회연합회 학술발표대회논문집
    • 간기
      부정기
    • 수록기간
      2005~2013
    • 십진분류
      KDC 540 DDC 690