초록

영어
Recently, the building envelope design on high-rise building does not consider energy-saving method and improvement of IAQ(Indoor Air Quality). It focuses on architectural design and methodological simplicity for building construction.
Therefore, a curtain wall system which has weakness on thermal performance is appled on building envelope system. Mostly the building heating/cooling load from outside environment is dominated on building envelope, however, the building design stage does not regard the efficient energy saving plan. It is because that there is no practical building envelope system which satisfies both energy-saving and indoor environment improvement in building.
In this research, the air-barrier-type perimeterless HVAC system installed on IT center building under construction in Seoul is studied with CFD simulation for the field applicable investigation.

목차

Abstract
 1. 서론
 2. 에어베리어형 페리미터레스 공조시스템 개요
 3. CFD 시뮬레이션
  3.1 CFD 시뮬레이션 개념
  3.2 CFD 시뮬레이션 결과
 4. 결론
 참고문헌