Earticle

다운로드

고단열 삼중창 시스템의 열관류율 성능평가 연구
A Study on the U-Value Evaluation of Super Insulation Triple Glazing Window System

원문정보

초록

영어
Window System has a problem with insulation on building wall comparison with other portions. Recently, in all over the world, technologies and research for improvement of insulation performance with window system were actively studied. This study has been considered about components of window system and evaluated insulation performance of triple window system through the tests of U-Value of window system and simulated model. It was evaluated window
system that widely used in domestic or overseas. Therm5.0 and Window6.0 were used for simulation available for heat analysis from stationary state of two-dimensional simulated model. As a result, the best components of each portion on window system were PVC frame, Plastic spacer and Low-e glass and the super insulation window system was triple glazing window system applied these components. The U-Value of this super insulation triple window system was 1.325 W/㎡K and it will be expected saving energy window system.

목차

Abstract
 1. 서론
 2. 창호의 단열성능 영향요소 사용현황
  2.1 Air Space
  2.2 간봉(spacer)
  2.3 유리
  2.4 창틀(frame)
 3. 창호의 단열성능실험과 시뮬레이션보정
  3.1 삼중창 시스템의 열관류율 실험
  3.2 시뮬레이션 보정
 4. 고단열 삼중창 시스템의 열관류율 평가
  4.1 프레임의 변화에 따른 열관류율 평가
  4.2 간봉에 따른 열관류율 평가
  4.3 유리두께별 열관류율 평가
  4.4. 유리의 방사율에 따른 열관류율 평가
  4.5 고단열 삼중창 시스템의 열관류율
 5. 결론
 참고문헌

저자

  • 박재성 [ Park Jae-Sung | 한밭대 대학원 건축공학과, 석사과정 ]
  • 안영섭 [ An Young-Sub | 한밭대 대학원 건축공학과, 석사과정 ]
  • 김병수 [ Kim Byoung-Soo | 한밭대 건축공학과 교수, 공학박사 ]
  • 윤종호 [ Yoon Jong-ho | 한밭대 건축공학과 교수, 공학박사 ]
  • 홍성철 [ Hong Sung-Chul | (주)AluENC 대표이사 ]

참고문헌

자료제공 : 네이버학술정보

    간행물 정보

    • 간행물
      대한건축학회지회연합회 학술발표대회논문집
    • 간기
      부정기
    • 수록기간
      2005~2013
    • 십진분류
      KDC 540 DDC 690