Earticle

다운로드

실증 실험을 통한 방화문 두께 변화가 기밀성과 단열 성능에 미치는 영향
An Experimental Study on the Effects of Fire Door Thickness on Airtightness and Thermal Insulation Performance

  • 간행물
    대한건축학회연합논문집 KCI 등재 바로가기
  • 권호(발행년)
    제28권 제1호 통권 131호 (2026.02) 바로가기
  • 페이지
    pp.29-35
  • 저자
    장운성
  • 언어
    한국어(KOR)
  • URL
    https://www.earticle.net/Article/A480493

원문정보

초록

영어
This study experimentally investigated the effects of fire door thickness on airtightness and thermal insulation performance for apartment unit entrance doors. Fire door specimens with thicknesses of 45, 55, 65, and 75 mm were tested for airtightness in accordance with KS F 2292 and for thermal transmittance in accordance with KS F 2278. The airtightness test results showed that all specimens satisfied the Grade 1 requirement. However, no consistent reduction in infiltration rate was observed with increasing door thickness. In contrast, thermal insulation performance exhibited a clear dependence on thickness. The thermal transmittance (U-value) decreased from 1.58 [W/(m²·K)] at 45 mm to 1.23 [W/(m²·K)] at 75 mm. Regression analysis revealed a strong negative correlation between door thickness and thermal transmittance (r = −0.958, p < 0.05). These results indicate that airtightness and thermal insulation performance respond differently to changes in fire door thickness.

목차

Abstract
1. 서론
1.1 연구배경 및 목적
1.2 연구범위 및 방법
2. 이론적 고찰
2.1 방화문의 기능적 특성과 열적 성능 요구
2.2 기밀성과 단열성의 기술적 정의 및 특성
2.3 관련 선행연구 고찰
3. 실험개요
3.1 시험체 구성
3.2 기밀성 시험
3.3 단열성 시험
4. 시험결과 및 분석
4.1 기밀성 시험 결과
4.2 단열성 시험 결과
4.3 시험 분석 결과
5. 결론
REFERENCES

저자

  • 장운성 [ Jang, Un-Seong | 사람과안전 건설화재에너지연구원, 수석연구원 ] Corresponding Author

참고문헌

자료제공 : 네이버학술정보

    간행물 정보

    • 간행물
      대한건축학회연합논문집 [Journal of the Regional Association of Architectural Institute of Korea]
    • 간기
      격월간
    • pISSN
      1229-5752
    • 수록기간
      1999~2026
    • 등재여부
      KCI 등재
    • 십진분류
      KDC 540 DDC 690