Earticle

다운로드

동절기 외부 환경으로부터 입실한 피험자의 체온 측정에 관한 연구
A Study on Body Temperature Measurement of Subjects who Moved from Outdoor Environment in Winter

  • 간행물
    대한건축학회연합논문집 KCI 등재 바로가기
  • 권호(발행년)
    제24권 제4호 통권 110호 (2022.08) 바로가기
  • 페이지
    pp.39-45
  • 저자
    정근주, 이규남
  • 언어
    한국어(KOR)
  • URL
    https://www.earticle.net/Article/A416410

원문정보

초록

영어
The body temperature after walking in a cold environment may appear lower than when it is measured under stable indoor conditions. In order to improve the accuracy of detecting abnormal body temperature for COVID-19 pandemic situation, it is important to measure the accurate body temperature of subjects who enter the buildings. To do this, the body temperatures of 19 subjects were measured and analyzed immediately after walking for 15 minutes in a cold environment (7℃) and at rest in a climate chamber (20 ℃) for 15 minutes. As a result of measuring the subject's eardrum temperature with an eardrum thermometer, it was found that 36.3℃ (S.D. 0.50℃) immediately after walking in a cold environment, 36.8℃ (S.D. 0.42℃) after stabilization, and a difference of 0.5℃. As a result of measuring the subject's forehead temperature with non-contact infrared thermometers A, B, and C, immediately after walking in a cold environment, they were 36.3℃ (S.D. 0.27℃), 36.3℃ (S.D. 0.27℃), and 36.2℃ (S.D. 0.33℃), respectively, and after resting, 36.7℃, (S.D. 0.27℃), 36.6℃ (S.D. 0.20℃), 36.8℃ (S.D. 0.41℃), respectively, the difference was 0.4℃. As a result of measuring the subject's forehead skin temperature with a contact skin thermometer, it was found to be 31.0℃ (S.D. 1.57℃) immediately after walking in a cold environment, 33.2℃ (S.D. 1.43℃) after stabilization, and a difference of 2.2℃. The difference between the forehead contact skin temperature and the eardrum temperature was 5.3℃ immediately after walking in a cold environment and 3.6℃ after stabilization. In conclusion, it is thought that some correction is necessary when discriminating abnormal body temperature with a non-contact infrared thermometer in winter.

목차

Abstract
1. 서론
1.1 연구 배경 및 목적
1.2 연구의 방법 및 범위
2. 인체의 체온 및 온도계 선행 연구
2.1 인체의 열평형 이론
2.2 비접촉 적외선 온도계 선행 연구
3. 피험자 인체 온도 측정 실험
3.1 온도계 및 피부온도 측정기 준비
3.2 피험자 및 착의량
3.3 실험 절차 및 체온 측정 환경
4. 체온 측정 결과
4.1 고막 온도 측정 결과
4.2 비접촉식 적외선 체온 측정결과
4.3 접촉식 피부온도 측정 결과
4.4 토론
5. 결론
REFERENCES

저자

  • 정근주 [ Jung, Gun-Joo | 부경대학교 건축공학과 교수, 공학박사 ]
  • 이규남 [ Rhee, Kyu-Nam | 부경대학교 건축공학과 부교수, 공학박사 ] Corresponding author

참고문헌

자료제공 : 네이버학술정보

    간행물 정보

    • 간행물
      대한건축학회연합논문집 [Journal of the Regional Association of Architectural Institute of Korea]
    • 간기
      격월간
    • pISSN
      1229-5752
    • 수록기간
      1999~2026
    • 등재여부
      KCI 등재
    • 십진분류
      KDC 540 DDC 690