Earticle

다운로드

큰느타리 재배사에서 헤파필터 교체 이후 기간에 따른 미생물상 변화
Changes in microbial phase by period after hepa filter replacement in King oyster(Pleurotus eryngii) mushroom cultivation

원문정보

초록

영어
This study was conducted to set up a proper replacement cycle of High Efficiency Particulate Air (HEPA) filters by observing the microbial populations in the air of the cultivation house of Pleurotus eryngii, before and after HEPA filter replacement at different periods . The density of bacteria and fungi in the air during each cultivation stage was measured using a sampler before the replacement of the HEPA filter. The results showed that airborne microorganisms had the highest density in the mushroom medium preparation room, with 169.7 CFU/m3 of bacteria and 570 CFU/m3 of fungi, and the removed old spaun had 126.3 CFU/m3 of bacteria and 560 CFU/m3 of fungi. The density of bacteria and fungi in the air at each cultivation stage before the replacement of the HEPA filter was 169.7 CFU/m3 and 570 CFU/m3, and 126.3 CFU/m3 and 560 CFU/m3, during the medium production and harvesting processes, respectively. After the replacement of the HEPA filter, the bacterial density was the lowest in the incubation room and the fungal density was the lowest in the cooling room. The microbial populations isolated at each period consisted of seven genera and seven species before the replacement, including Cladosporium sp., six genera and six species after 1 month of replacement, including Penicillium sp., 5 genera and 7 species after 3 months of replacement, including Mucor plumbeus, and 5 genera and 12 species, 5 genera and 10 species, and 5 genera and 10 species, 4, 5, and 6 months after the replacement, respectively, including Penicillium brevicompactum. During the period after replacement, the species were diversified and their number increased. The density of airborne microorganisms decreased drastically after the replacement of the HEPA filter. Its lowest value was recorded after 2 months of replacement, and it increased gradually afterwards, reaching a level similar to or higher than that of the pre-replacement period. Therefore, it was concluded that replacing the HEPA filter every 6 months is effective for reducing contamination.

목차

ABSTRACT
적요
REFERENCES

저자

  • 박혜성 [ Hye-Sung Park | 농촌진흥청 국립원예특작과학원 인삼특작부 버섯과, 단국대학교 자연과학대학 미생물 학과 ] Corresponding Author
  • 민경진 [ Gyong-Jin Min | 농촌진흥청 국립원예특작과학원 인삼특작부 버섯과 ]
  • 이은지 [ Eun-Ji Lee | 농촌진흥청 국립원예특작과학원 인삼특작부 버섯과 ]
  • 이찬중 [ Chan-Jung Lee | 농촌진흥청 국립원예특작과학원 인삼특작부 버섯과 ]

참고문헌

자료제공 : 네이버학술정보

    간행물 정보

    • 간행물
      한국버섯학회지 [Journal of MUSHROOMS]
    • 간기
      계간
    • pISSN
      1738-0294
    • eISSN
      2288-8853
    • 수록기간
      2003~2025
    • 등재여부
      KCI 등재
    • 십진분류
      KDC 525 DDC 635