Factors governing heavy weight floor impact sound insulation in apartments having hard floor and wall-slab structure with shallow slabs

  • 간행물
    대한건축학회연합논문집 KCI 등재 바로가기
  • 권호(발행년)
    제16권 제2호 통권 60호 (2014.04) 바로가기
  • 페이지
    pp.167-173
  • 저자
    Yang Ki Oh, Mun Ki Chu
  • 언어
    영어(ENG)
  • URL
    https://www.earticle.net/Article/A217729

원문정보

초록

영어
There are two distinct features in Korean apartments. The first is Ondol, a floor radiant panel heating system that consists of an array of heating coils buried into a hard mortar finish. This allows residents to stand on the hard floor without shoes on. Next is a structural system composed of load bearing walls and slabs instead of beams and columns. Bare feet on hard surfaces cause severe noise from their impact with the floor. Furthermore, the tight and wide bonding between the slabs and the load bearing walls effectively transmits noise to the rooms underneath. This type of impact source cannot be simulated by a standard tapping machine, and may not be efficiently protected by usual floating floors. Four standard floor structures were introduced in the building code established in 2005 and all have 210mm thick floor slabs,. However, there are over five-million apartment units built before 2005, most of them having 135mm slabs. This study deals with a systematic approach to improve the performance of insulation used to absorb impact noise for apartments having shallow 135mm slabs. The construction between floors is investigated, specifically the following four components and their roles: Suspended ceiling and plenum (slab and its stiffness), thickness of the slab, the floor floating system, and resilient panel (for Ondol) support system.

목차

Abstract
 1. INTRODUCTION
 2. HEAVY IMPACT NOISE ON FLOORS
  2.1 PROBLEM OF HEAVY IMPACT NOISE ON FLOORS
  2.2 STANDARD HEAVY IMPACT SOURCE
  2.3 MEASUREMENT OF HEAVY IMPACT NOISE
  2.4 RATING OF HEAVY IMPACT NOISE INSULATION
  2.5 LAWS ON HEAVY FLOOR IMPACT NOISE
  2.6 REGUALATIONS ON HEAVY IMPACT FLOOR NOISE
 3. HEAVY IMPACT FLOOR NOISE PROBLEMS IN SHALLOW SLAB APARTMENTS
 4. FACTORS GOVERNING HEAVY FLOOR NOISE INSULATION
  4.1 MASS OF THE CONCRETE SLAB
  4.2 STIFFNESS OF A CONCRETE SLAB
  4.3 RESILIENT FLLOR SUPPORT SYSTEM FOR PREFAB PANELS
  4.4 CEILING AND ITS PLENUM
 5. DISCUSSIONS
 ACKNOWLEDGEMENTS
 REFERENCES

저자

  • Yang Ki Oh [ Professor, Department of Architecture, Mokpo National University ]
  • Mun Ki Chu [ Professor, Department of Architecture, Chodang University ] Corresponding author

참고문헌

자료제공 : 네이버학술정보

    간행물 정보

    • 간행물
      대한건축학회연합논문집 [Journal of the Regional Association of Architectural Institute of Korea]
    • 간기
      격월간
    • pISSN
      1229-5752
    • 수록기간
      1999~2026
    • 등재여부
      KCI 등재
    • 십진분류
      KDC 540 DDC 690