Earticle

다운로드

한중환경시 갱폼 거푸집 내부 철근의 온도변화
Temperature History of Steel bars Located in a Gang Form Before Placing Concrete During a Cold Weather Condition

원문정보

초록

영어
This research measured the temperature variations of gang form rebars within the mold during a cold weather condition. The summarized results are as follows: regardless of the diameter of the rebar, it was found to be –13~-15℃ before the sunrise where the outside temperature was around 2℃ which did not seem to affect the rebar temperature. The temperature of rebar was found to be rising beginning 8 AM as the sun rises and reached above freezing temperature two and a half hours later around 10 AM. The temperature began to rise in the order of smaller rebar diameter progressing up to the larger diameter and reached the maximum temperature around 2 PM. The temperature of most rebars decreased close to the outside temperature by 8 PM.

목차

Abstract
 1. 서론
 2. 실험계획 및 방법
  2.1 실험계획
  2.2 실험방법
 3. 실험결과 및 분석
  3.1 온도이력 특성
 4. 결론
 참고문헌

저자

  • 김경훈 [ Kim, Kyoung-Hoon | 정회원, 청주대학교 건축공학과 석사과정 ]
  • 허영선 [ Heo, Young-Sun | 정회원, 청주대학교 산업과학연구소, 전임 연구원 ]
  • 한민철 [ Han, Min-Cheol | 정회원, 청주대학교 건축공학과 부교수, 공학박사 ]
  • 한천구 [ Han, Cheon-Goo | 정회원, 청주대학교 건축공학과 교수, 공학박사 ]

참고문헌

자료제공 : 네이버학술정보

    간행물 정보

    • 간행물
      대한건축학회지회연합회 학술발표대회논문집
    • 간기
      부정기
    • 수록기간
      2005~2013
    • 십진분류
      KDC 540 DDC 690