Earticle

다운로드

부식된 철근을 사용한 모르타르 중의 철근 부식 측정
A Measurement of Steel Corrosion in Mortar-Embedded Corroded Steel

  • 간행물
    대한건축학회지회연합회 학술발표대회논문집 바로가기
  • 권호(발행년)
    2011년도 추계학술발표대회 (2011.10) 바로가기
  • 페이지
    pp.300-304
  • 저자
    이상호
  • 언어
    한국어(KOR)
  • URL
    https://www.earticle.net/Article/A167266

원문정보

초록

영어
In order to measure the corrosion of steel in mortar-embedded corroded steel, nondestructive techniques such as the electro-potential method and the transient electro-magnetic(TEM) method were adapted. After steels were corroded by the salt spray during 0, 4, 8, 15, 25days, they were embedded in mortar which were made form water : cement : sand ratio of 0.5 : 1 : 2. The mortar specimen was 50㎝ long, 20㎝ wide and 10㎝ thick.
The contents of result acquired in this study are as follows.
(1) The variation of the potentials and the secondary electro-magnetic forces were shown by change of steel surface with different corrosion time of steel
(2) The values of the potential of mortar specimen embedded steel were increased with cover depth and the values of the secondary electro-magnetic force of that were .decreased with cover depth

목차

Abstract
 1. 서론
 2. 자연전위법
 3. 과도전자탐사법
 4. 시험편 제작 및 실험방법
  4.1 시험편 제작
  4.2 실험방법
 5. 실험결과 및 고찰
  5.1 부식정도에 따른 전위와 2차기전력의 변화
  5.2 피복두께에 따른 전위와 2차기전력의 변화
 6. 결론
 참고문헌

저자

  • 이상호 [ Lee, Sang-Ho | 한중대 건축공학과 교수, 공학박사 ] 교신저자

참고문헌

자료제공 : 네이버학술정보

    간행물 정보

    • 간행물
      대한건축학회지회연합회 학술발표대회논문집
    • 간기
      부정기
    • 수록기간
      2005~2013
    • 십진분류
      KDC 540 DDC 690