Earticle

다운로드

Mock-Up에 의한 공조용 디퓨져 유형별 기류 특성 분석
Analysis of Air Pattern from Different Type of Diffuser Shape by Mock-Up Test

원문정보

초록

영어
Peoples live the most of the day in an indoor. Therefore, the various technical system is used in order to be agreeable more and efficiently maintain the inner climate. Diffuser is played the important role among the air conditioner and it has enough to note as to a selection. Recently, the predictive assessment of the indoor thermal environment in which we use CFD and air environment is actively made. And the result of being performed by carefully considering the air specific of a diffuser is rare. Therefore, in this, each type of the diffuser for indoor air specific was carefully analyzed. It expects to be used as the boundary condition of a diffuser, when the predictive assessment of the indoors thermal environment and air environment is made by using CFD.

목차

Abstract
 1. 서론
 2. 다퓨져의 유형별 특성 및 선정
  2.1. 다퓨져의 유형별 특성
  2.2. 실험대상 디퓨져의 선정
 3. 실험개요 및 측정방법
  3.1. Mock-up 모델의 구성
  3.2. 측정조건 및 방법
 4. 실험결과 및 고찰
  4.1. 실내 기류속도 측정 결과
  4.2. 기류가시화 실험 결과
 5. 결론
 참고문헌

저자

  • 김호진 [ Kim, Ho-Jin | 영남대학교 대학원 건축학부, 석사과정 ]
  • 최동호 [ Choi, Dong-Ho | 대구가톨릭대학교 건축학과교수, 공학박사 ]
  • 석호태 [ Seok, Ho-Tae | 영남대학교 건축학부 부교수, 공학박사 ]
  • 양정훈 [ Yang, Jung-Hoon | 영남대학교 건축학부 조교수, 공학박사 ] 교신저자

참고문헌

자료제공 : 네이버학술정보

    간행물 정보

    • 간행물
      대한건축학회연합논문집 [Journal of the Regional Association of Architectural Institute of Korea]
    • 간기
      격월간
    • pISSN
      1229-5752
    • 수록기간
      1999~2026
    • 등재여부
      KCI 등재
    • 십진분류
      KDC 540 DDC 690